Kamstrup HC-003-56 Installation Manual Download Page 6

Installation guide

Kamstrup A/S • 55123402_A1_EN_12.2022

6

2G/4G Network Module • HC-003-80

2  The CALL function

Press and hold down the two outermost push buttons on 
the calculator until the display shows “CALL”, and release 
the buttons after 3 seconds. 

After maximum 1 minute, the display must show “OK” in 
the bottom left corner, indicating connection with READy 
Manager.

You can use the meter’s display to read out the meter’s connection information. If the second digit in display menu 47 is 1 or 
below, you must move the antenna to a better location. In some circumstances, it may be necessary to extend the cables and 
to use an antenna with SMA connector as shown in Table 1 on page 7.

3  Accessing “TECH loop”

Press and hold the middle button down until the display 
shows “1-User”.

Push the right arrow button until the display shows 
“2-Tech” and confirm by pressing the middle button to 
access “TECH loop”.

4  Accessing connection information

Press the buttons to access menu 2-101-03 and to read 
out menu index 47.

Verify the data in the table below.

Summary of Contents for HC-003-56

Page 1: ...Kamstrup A S 55123402_A1_EN_12 2022 NB IoT and 2G 4G modules HC 003 56 and HC 003 80 Installation Guide...

Page 2: ...K 8660 Skanderborg Denmark All rights reserved The graphics and content in this document are the copyrighted work of Kamstrup and contain proprietary trademarks and trade names of Kamstrup Third parti...

Page 3: ...3 2G 4G Network Module HC 003 80 Contents 1 Prerequisites 4 2 Mounting of meter and antenna 5 1 Mounting the module 5 2 The CALL function 6 3 Access to TECH loop 6 4 Access to connection information...

Page 4: ...several devices have been imported The date of the last reception of data is shown and if there is a problem with the device a red triangle appears For the marked module there has not been contact yet...

Page 5: ...ounted without sharp bends It is important that the antenna is mounted as high as possible and with large distance to other antennas and steel pipes to avoid noise and disturbances If the meter is mou...

Page 6: ...connection information If the second digit in display menu 47 is 1 or below you must move the antenna to a better location In some circumstances it may be necessary to extend the cables and to use an...

Page 7: ...e infrastructure 9 Connected to the NB IoT infrastructure The second digit indicates the connection quality 0 Very poor 1 Poor 2 Fair 3 Good 4 Excellent 1 Note that this information is a snapshot at o...

Page 8: ...l number of the meter or the module 3 Press the button Test the connection Display information Menu index 49 can also be helpful in troubleshooting 4 4 1 2 x01 4 Module status Menu Menu index Informat...