background image

Kampmann.ca/Katherm-QE

Kampmann Heating, Cooling, Ventilation Ltd

1628 West 1st Ave 
Vancouver, BC
Canada V6J 1G1

T

  +1 604 789 5779

E

 [email protected]

W

   Kampmann.ca

Kampmann GmbH

Friedrich-Ebert-Str. 128 - 130
49811 Lingen (Ems)
Germany

T

  +49 591 7108-660

F

  +49 591 7108-173

E

 [email protected]

W

   Kampmann.eu

I535/08/18 US I SAP-Nr. 1280354

Summary of Contents for Katherm QE

Page 1: ...Katherm QE Tangential fan convection with electric heating element Assembly and installation instructions Keep these instructions in a safe place for future use I535 08 18 US I SAP Nr 1280354...

Page 2: ...one involved with the installation commissioning and use of this product is obliged to pass these instructionsontotradespeople who are involved at the same time or subsequently as well as to end users...

Page 3: ...e is deemed not to be correct and intended Any damage resulting from this is the sole responsibility of the operator of the unit Correct and proper use is also deemed to include compliance with the in...

Page 4: ...erate the heater after it malfunctions Disconnect power at service panel and have the heater inspected by a reputable electrician before reusing Do not use outdoors Do not insert or allow foreign obje...

Page 5: ...the Katherm QE with the convector on the window side Important The height adjustment feet are already fitted to the floor trench They are fixed the wrong way round for transport reasons To install an...

Page 6: ...here are no sound bridges to the concrete slab especially close to the height adjustment feet appropriate materials have been used to seal all openings and punched openings in the trench heater from t...

Page 7: ...a tool The grille fixing only needs to be removed on one side at the electrical connection side when wiring Refit the grille fixing once the unit has been wired Installation cover Important Never oper...

Page 8: ...nection openings Heat outputs Katherm QE Design 1 Roll up grille 2 Electrical wiring 3 EC tangential fans 4 Electric heating element with air baffles 5 Power control 6 Safety chain Room side connectio...

Page 9: ...the usual measuring and audible range Fan stage Control signal Heat output Electrical power consumption fan Current consump tion Sound pressure level 1 Sound power level V W W A dB A dB A Trench lengt...

Page 10: ...e unit make sure the power has been turned off at the circuit breaker panel and that the heating element is cool Any other servicing than the mentioned shall be performed by an authorized service repr...

Page 11: ...s Technical Wiring Regulations Only connect the unit to fixed cables Important note Provide an all pole mains separator in the wiring on site that can be reliably secured to avoid the system being rec...

Page 12: ...rol or a building management system Group control of several trenches is possible without the need for additional accessories The Katherm QE should be connected or switched in parallel in accordance w...

Page 13: ...controller Product features flat surface mounted housing colour pure white similar to RAL 9010 operating voltage 24 V AC DC 50 Hz 2 output signals 0 10 V max 5 mA protection class IP 30 control range...

Page 14: ...Functional description The factory setting activates the electric heating element with a heat output of 20 and at the same time the EC tangential fan with minimum fan revolution at a control voltage o...

Page 15: ...vin above the room temperature is maintained in accordance with IEC EN 60335 2 30 The triggering of the safety temperature monitor can be signalled via a potential free fault alert contact After recti...

Page 16: ...M1 Typ146928 room thermostat 1 2 3 4 B1 0 10V GND control signal 0 10VDC 0 2 0V device OFF 2 0 9 5V 0 to 100 heating output N1 R1 HRR V3 US L N C NONC DI1Gnd 24V AI1Gnd AI2 Gnd Gnd Uc 24V Err RPM STB...

Page 17: ...ired DIP 2 OFF OFF speed increase OFF ON speed increase ON DIP 3 OFF OFF min heating capacity 20 ON min heating capacity 30 DIP 4 OFF N1 HRR V3 US L N C NONC DI1 Gnd 24V AI1 Gnd AI2 Gnd Gnd Uc 24V Err...

Page 18: ...cription Fits trench length Type number 825 mm 1250 mm 1700 mm Electrical power module X X X 000001264781 Electrical PCB X X X 000001246305 Electrical heating element X 000001264764 X 000001264752 X 0...

Page 19: ......

Page 20: ...1628 West 1st Ave Vancouver BC Canada V6J 1G1 T 1 604 789 5779 E info kampmann ca W Kampmann ca Kampmann GmbH Friedrich Ebert Str 128 130 49811 Lingen Ems Germany T 49 591 7108 660 F 49 591 7108 173 E...

Reviews: