background image

Main features     

 

 

Speed range

 

0.1- 400RPM

 

Speed resolution

 

0.1RPM

 

Flow range 

≤450ml/min 

Direction control 

Support  clockwise  and  counterclockwise 
operation 

Display mode 

LED 4-digit digital tube 

Control mode

 

Encoder, toggle switch, external analog signal 
control,  RS485  communication  control,  foot 
switch control 

External analog 

signal control

 

4-20mA, 0-5V

 

Power failure 

parameter memory

 

support

 

Working mode

 

Speed mode, Flow mode

 

Way of working 

Fully  automatic  circulation,  semi-automatic 
circulation, manual 

Support function

 

Start  and  stop,  forward  and  reverse,  speed 
adjustment, etc.

 

Power supply mode 

External power adapter 

Power

 

<50W

 

 

Working conditions 

 

 

Ambient temperature:

 -20℃~60℃

 

 

Rated voltage:

 DC24V

 

 

Maximum current:

 2A

 

 

Summary of Contents for DIPump550

Page 1: ...DIPump550 intelligent peristaltic pump User Manual 2022 01 12 V1 4 Kamoer Fluid Tech Shanghai Co Ltd www kamoer com...

Page 2: ......

Page 3: ...ol RS485 communication control foot switch control External analog signal control 4 20mA 0 5V Power failure parameter memory support Working mode Speed mode Flow mode Way of working Fully automatic ci...

Page 4: ...ng the last three digits indicate the currently set working time When the first digit shows no beating the last three digits indicate the current remaining working time When the first digit is display...

Page 5: ...ristaltic pump when dialed to the left the pump rotates counterclockwise when it is dialed to the right the pump rotates clockwise The switch is ineffective during the operation of the peristaltic pum...

Page 6: ...cally 6 Press the encoder not long press the pump will run according to the set running time and stop time Note When the pump starts to cycle the digital tube displays the time countdown and follows 1...

Page 7: ...nd the running flow and stop time will be saved automatically 6 Press the encoder not long press the pump will run according to the set Operating flow and stop time 7 Press the encoder not long press...

Page 8: ...igits of 1 8 correspond to 8 different functions Select the function to be set and press the rotary encoder to enter the detailed setting interface of the function Specific function settings Note In t...

Page 9: ...here is no need to set this item Interface Setting Introduce Low level mode When the direction button is turned counterclockwise but the pump actually rotates clockwise select 0 to adjust the pump to...

Page 10: ...rform pump head flow calibration After entering the setting interface the calibration speed and calibration time will switch back and forth every 2 seconds the first digit shows 4 the middle one space...

Page 11: ...g interface and you can set the analog selection The last digit represents the analog option Interface Setting Introduce 0 5V 4 20mA 485 mode C007 Suction back function In the function selection inter...

Page 12: ...g interface and the drive enable setting can be performed The last digit represents the enable option Interface Setting Introduce Low level enable High level enable C009 Maximum speed setting This fun...

Page 13: ...gnal control mode Control the board by analog signal mode 0 5V 4 20mA Please connect the signal line according to the actual control mode Pin 1 reserved Pin 2 485 B Pin 3 485 A Pin 4 Foot switch Pin 5...

Page 14: ...452 Note the maximum flow in the above chart is obtained by testing water at 400 rpm with a new pump pipe aged for 30 minutes at room temperature about 25 for reference only Ambient temperature mater...

Page 15: ......

Page 16: ...Kamoer Fluid Tech Shanghai Co Ltd Add 4th Building No 49 Xiangjing Road Songjiang District Shanghai China Phone 86 021 67742578 Fax 86 021 67741776 Website www kamoer com...

Reviews: