ELECTRICAL PRUNING SHEAR
74
www.kamikazevolpi.com
13. Secure gear nut with clip and
insert bolt.
11. Place gear nut on center bolt.
14. Tighten gear nut clip bolt
securing the centerbolt gear nut.
12. Tighten gear nut with cresent
wrench.
15.3 TOOL CALIBRATION
If a repair replacement motor or drive plate is required, the pruners need to
be recalibrated. Follow next steps to perform the calibration:
1. Remove the upper and lower blades.
2. Insert the battery.
3. Hold down the trigger and remain motionless. Press the POWER switch again.
4. The trigger remains motionless for more than 20 seconds.
Summary of Contents for KV 300