14
Leak Testing Procedure
1. Prepare a leak testing solution of sudsy water by mixing a solution of half
liquid soap and half water in a spray bottle.
2. Check and make sure all the control knobs are in the “OFF” position.
3. Turn cylinder valve knob counter clockwise one turn to open.
4. Apply leak-testing solution by spraying on joints of the gas delivery system.
5. Blowing bubbles in the soap solution indicates that a leak is present.
6. Stop a leak by tightening the loose joint or by replacing the faulty part with
a replacement part recommended by the manufacturer. Do not attempt to
repair the cylinder valve if it becomes damaged. The cylinder must
be replaced.
7. If you are unable to stop a leak, shut off the gas supply at the cylinder
valve. Remove the cylinder from the grill. Call an authorized gas appliance
service technician or LP gas dealer. Do not use the appliance until the leak
is corrected.
8. Push in and turn any control knob to release pressure in the hose and
manifold.
9. Turn off the control knob.
PRE-USE CHECKLIST
Leak Testing Procedure
DANGER
To prevent fire or explosion hazard, DO NOT smoke or allow any potential source of ignition
(sparks, electrical arcing, etc) in the area while performing a leak test. Leak test should be
conducted outdoors only. Never conduct a leak test using a fire or flame.
Perform a leak test at least once each year whether the gas supply cylinder has been
disconnected or not. In addition, anytime the gas cylinder is connected to the regulator or
any part of the gas system is disconnected or replaced, conduct a leak test. Use only a leak
testing solution as specified below.
Summary of Contents for ComboJoe CGJ26
Page 1: ...ComboJoe GasJoe Models GJ26 CGJ26 GJ32S CGJ32S GJ38S KAMADOJOE COM...
Page 18: ...15 Figure 10 Figure 11...
Page 31: ...28...
Page 32: ...29 EXPLODED PARTS VIEW ComboJoe 26 GasJoe 26...
Page 34: ...31 EXPLODED PARTS VIEW ComboJoe 32 GasJoe 32...
Page 36: ...33 EXPLODED PARTS VIEW GasJoe 38...
Page 38: ...KAMADO JOE 2865 North Berkeley Lake Road NW Suite 6 Duluth Georgia 30096 USA CJ GJ Rev 08 11...