Mounting : 
Orientation: 

This fixture should only be mounted/used on a flat surface. This fixture should not be tilted. 

Rigging: 

It is important never to obstruct the vents’ pathways. Mount the fixture using, a suitable “C” or “O” type clamp. 

When selecting installation location, take into consideration the fluid reservoir access and routine maintenance. 
Safety cables must always be used, utilising the provided safety eye bolt. 

Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation. 

 
General maintenance 

To maintain optimum performance and minimise wear, the item should be cleaned frequently. Usage and environment are 
contributing factors in determining the cleaning frequency. As a general rule, fixtures should be cleaned after use to avoid dust build-

up and blockages, which can result in poor performance, overheating and breakages. Be sure to uplug the unit from the mains 

before

 conducting any maintenance. Use a vacuum and a soft brush to remove dust collected on external vents and internal 

components. Clean the external case when the unit has 

completely

 cooled down with a dry cloth or tissue.  

 

Regular maintenance 

Be sure to power off fixture 

before

 conducting any maintenance. Every 40 hours of continuous operation, it is recommended to run a 

cleaning solution

 composed of 80% 

distilled

 water and 20% distilled 

white vinegar

 through the system to prevent the 

accumulation of particulate matter in the heating element. 
The recommended cleaning regime is as follows: 
1. Empty all haze/smoke fluid from the machine.  
2. Add the above 

cleaning solution

 to the tank (80% 

distilled

 water and 20% distilled 

white vinegar

).  

3. Plug the unit in to the mains and allow it to warm up.  
4. Run the unit in a well-ventilated area until the tank is almost empty. 

Do not allow the pump to run dry.

  

Cleaning is now complete. Refill with haze/smoke fluid. Run the unit briefly to clear any cleaning solution from the system. 

 

 
Trouble shooting 

Symptom 

Solution 

No Power 

Check mains power. 
Check external fuse. 
Check internal fuse. 

No smoke output 

Check fluid level. 
Check remote. 
If using wireless, check batteries. 

Breaker/fuse keeps blowing 

Possible electrical short. Contact retailer/distributor for further instructions. 

Low smoke output 

Run a cleaning solution through the smoke machine. 
Check that the smoke machine is plugged into the correct voltage. 

Smoke machine is not heating up 

Check the external fuse / check the internal fuse. 
Possible faulty part. Contact your retailer/distributor for further instructions. 

Remote does not work 

Make sure connector is firmly connected to device. 
Possible faulty controller / try using another controller. 
Check the external fuse / check the internal fuse. 

LED fluid indicator states no 
smoke but the container if full 

Try resetting the smoke machine by turning the power off and then on again. 
Possible faulty part. Contact retailer/distributor for further instructions. 

 

Features & spec 

Model 

Kam KSM1100 V2 

Power supply 

230V AC - 50Hz 

Power 

900w 

Fuse 

F5A 

Re-heat time 

3 minutes 

LED FX 

3 x red LED 

Output 

10,000 CuFt per minute 

Continue output  

Yes 

Tank Capacity 

0.8 litres 

Timer remote 

Yes 

Wireless remote  

Yes 

Gross weight 

4Kg 

 