Safety instructions
Please read the following notes carefully because they include important safety information regarding this product.
1. Always plug in the power plug last and disconnect from the mains when the device is not in use or before cleaning.
2. Do not install and operate the device in rain or extreme heat, moisture or dusty environments.
3. This device is for indoor use only and in a dry environment.
4. If the device has been exposed to drastic temperature fluctuations, do not switch the unit on immediately but wait until it reaches
room temperature.
5. Do not shake the device and avoid brute force when installing or operating.
6. Do not use the device during thunderstorms. Disconnect the unit from the mains.
7. Do not use solvents or aggressive detergent to clean the device. Use a soft, clean cloth.
8. Do not modify the device or the connected power cord.
9. In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs
carried out by unskilled people can lead to damage or malfunction. Please contact your Authorised Kam Retailer. Always use the
same type of spare parts.
10. Never connect the device to a dimmer pack.
11. Make sure the power cord is never crimped or damaged.
12. Never disconnect the power cord by pulling or tugging on the cord.
13. Avoid direct eye exposure to the LED light source while it is on.
14. Never drink the smoke/haze fluid.
15.
IMPORTANT – the smoke aperture on the unit can get VERY HOT. Never touch this area whilst the unit is in operation
and always leave the unit to cool down before touching the area.
1. Smoke aperture
6. Wireless remote LED
11. Green LED = warm up
2. LED back lights
7. Button 1 = Smoke / Buttons 2-4 = Off
12. Red LED = low fluid (add fluid now)
3. Safety eye bolt
8. Timer remote: set the duration smoke is released for 13. Wired remote control connection
4. Fluid tank
9. Timer remote: set time interval between output
14. Mains power input
5. Universal hanging bracket
10. Green LED = ready
15. Illuminated fluid indicator
Setup and operation
1. Unpack your unit then unscrew the top cap of the tank and move it to one side. Do no remove it from the hose.v
3. Fill the tank with smoke fluid (do not over fill the tank).
4. Screw on the cap securely. Ensure the hose reaches to the bottom of the bottle so a consistent flow of fluid is supplied to the unit.
5. Connect the wired remote control.
6. Connect the IEC mains cable to the rear of the unit and then to the mains power.
7. Heat up time is usually between 3-4 minutes. Please ensure no button is pressed during the heat up time.
8. When the machine is ready, the LED light on the rear of the unit will light up.
7. Press the button on the remote for 5 seconds so the fluid has a chance to flow through the heater. The unit is now ready to use.
8. It is recommended that the unit produces smoke with small pauses in between so that the temperature is maintained and the
thermostat doesn’t switch off.
9.
Wired remote
operation
- set the duration smoke is released for using the dip switches and then set the interval between output.
10.
Wireless remote operation
- press button 1 and the unit will output smoke for as long as you hold down the button.
When using either type of remote control, observe point 8. and do not run the unit for long periods of time without pausing.
Fuse Replacement:
Unplug the IEC power cable before replacing the fuse! Always replace with same type of fuse.
1. Using a flat head screwdriver, remove the fuse holder from the IEC housing. 2. Remove the bad fuse from the fuse holder.
3. Insert the new fuse into the fuse holder. 4. Install the fuse holder in the IEC housing.