97
EN
Maintenance and cleaning
◊ by the user /
•
by the authorised qualifi ed technical assistance
All cleaning of all parts must be carried out with the Insert completely cold and
unplugged to avoid burns and thermal shock. The Insert does not need much
maintenance if used with certifi ed quality pellet. The need for maintenance
varies depending on the conditions of use (switching on and off repeatedly) and
depending on the performance required.
It is recommended periodic monitoring
of the Insert to check its condition.
Parts
Everyday
Every 2-3
days
Every
week
Every 15
days
Every 30
days
Every 60-
90 days
Every 1
year
Brazier
◊
Cleaning the ash collection
compartment with suction device
◊
Cleaning ash tray
◊
Cleaning the interior heat exchanger /
smoke fan compartment
•
Cleaning complete exchanger
•
Clean "T" to exhaust
•
Flue
•
Door gasket ash
•
Internal parts
•
Flue pipe
•
Electromechanical components
•
The Insert requires a simple and thorough
cleaning in order to ensure a more effi cient
performance and smooth operation. While
cleaning the inside of the Insert, to prevent
the escape of ashes, you can start the fan fl ue
exhaust. Clean the grate from the ash and any
incrustation which could obstruct the passage
of air. In the case of depletion of pellets in the
tank,the burn pot may accumulate unburned
pellet. Always empty the residuals from the grate
before each start. Remember that only a brazier
located and clean properly can ensure ignition
and optimal operation of your Insert. When
positioning the crucible, carefully check that
the edges of the crucible adhere completely to
their place and that the hole coincides with the
tube dedicated to the passage of the resistance.
There must be no combustion residue in the
contact zone between the edges of the crucible
and the support surface on the sink-holder.
BY THE USER
Daily control
Summary of Contents for Paola 13-13D