INSTALLATION INSTRUCTIONS
60" x 32" Acrylic Air Bath
1107630-2-
C
19 of 28
Questions? Problems? For additional assistance, please contact KALLISTA’s Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.
13. MAKE POWER CONNECTIONS - REMOTE
Remote
Blower
Power Supply Cable
New Field
Cable To
Blower Motor
Second Junction Box
(Added for Remote Blower)
Blower Motor
Power Cord
Control Power
Junction Box
Control Power
Supply Cord
WARNING: Risk of electric shock.
To reduce the risk of electric shock, connect the control to a properly
grounded Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This will provide
additional protection against line-to-ground shock hazard. A dedicated 220-240 V, 15 A, 50/60 Hz circuit is
required.
WARNING: Risk of electric shock.
Make sure the power has been disconnected before performing the
following procedures.
NOTE:
The bath with airjets model number is printed on a label near the bath blower motor. This label also
identi
fi
es the electrical rating of the bath.
Ensure that the control power supply cord is properly routed to the control power junction box. The control
power supply cord contains a brown wire (Line 1), a blue wire (Line 2), and a green wire with a yellow stripe
(ground or earth).
Install a strain relief (not provided) for the power supply cable to the control power junction box.
Route the power supply cable to the control power junction box.
As required, strip the jacket and wire insulation on both cables in order to make the connections.
For installations in the United States, mark any white conductor in the supply power wiring with red or black
tape as required by the NEC.
Connect service to the control power junction box.
Provide a separate equipment earthing or grounding conductor to the spare earth/ground lug located on
the junction box. This conductor
must not
be connected to any current-carrying conductor. Follow local
electrical codes.
Bond in accordance with national and local codes.
Clean the area of all dust and debris.
All wiring harnesses have been pre-wired at the factory. Make sure all wires are securely fastened.
NOTE:
Your wiring harness includes an antenna for the optional remote control. Do not alter or damage this
antenna during installation.