background image

5. Install the Whirlpool

WARNING: Risk of personal injury.

This cast iron whirlpool is extremely heavy. Obtain sufficient

help to carefully lift and move it.

CAUTION: Risk of product damage.

Do not lift the whirlpool by the piping or pump, or use the

piping or pump for structural support of the whirlpool.

CAUTION: Risk of product damage.

Do not support the whirlpool by the rim.

Carefully move the whirlpool into position. Insert the drain tailpiece into the trap.

Level the whirlpool by fitting metal shims under the whirlpool feet as needed. Check for level along
the top of the whirlpool, and across the drain side. If the feet are not accessible from the back or
side, move the whirlpool in and out of position to shim it properly. Make sure the whirlpool is
resting on all four feet.

6. Cut the Pump Banding Straps

IMPORTANT! This step is necessary to make your whirlpool operate more quietly.

Use tin snips to cut the two pump banding straps from the whirlpool pump.

NOTE:

Do not raise the pump higher than it was before you cut the pump banding straps. If the pump is

raised too high, it will not prime properly. Make sure the rubber isolation feet are in place.

To minimize whirlpool noise and vibration, be sure the pump is not in direct contact with the
whirlpool after the pump banding straps are cut. The pump control contains rubber isolation feet to
reduce pump noise.

7. Install the Plumbing

CAUTION: Risk of property damage.

Ensure a watertight seal on the whirlpool drain.

Connect the drain to the trap according to the drain manufacturer’s instructions.

NOTICE:

An access panel will simplify future maintenance.

Install the faucet valving according to the faucet manufacturer’s instructions. Do not install the
faucet trim until instructed. Open the hot and cold water supplies, and check the supply
connections for leakage.

Run water into the whirlpool, and check the drain connections for leakage.

Level by fitting metal shims
under the feet.

Pump

Wiring
Harness

Control

Cut the pump banding straps.

Rubber Isolation Feet

1019455-2-E

8

Kallista

Summary of Contents for P50035

Page 1: ...Installation Guide Cast Iron Bath Whirlpool P50035 1019455 2 E ...

Page 2: ... circuit conductor supplying this equipment Pressure wire connectors are provided on the exterior of the junction box or control within this unit to permit connection of a bonding conductor between this unit and all other exposed metal in the vicinity as needed to comply with local requirements Grounding is required The unit should be installed by a qualified service representative and grounded Pr...

Page 3: ...tions and Service Access 3 Tools and Materials 3 Before You Begin 4 Roughing In Dimensions 5 Prepare the Site Concrete Construction 6 Prepare the Site Wood Construction 7 Prepare the Whirlpool 7 Install the Whirlpool 8 Cut the Pump Banding Straps 8 Install the Plumbing 8 Make Electrical Connections 9 Test Run the Whirlpool 10 Complete the Finished Wall Deck 11 Complete the Concrete Installation 11...

Page 4: ...support of the whirlpool CAUTION Risk of product damage Do not support the whirlpool by the rim This whirlpool is intended for drop in or alcove installation depending upon the model chosen Inspect the whirlpool for damage before you begin installation You must install this whirlpool to an adequately supported level subfloor Kallista reserves the right to make revisions in the design of products w...

Page 5: ...nsions 36 914 mm 20 7 8 530 mm Pump Control Access 24 610 mm W x 14 356 mm H 3 76 mm 1 1 2 OD 2 7 8 73 mm 2 1 2 64 mm 72 1829 mm 1 4 6 mm 4 3 8 111 mm 3 1 2 89 mm 18 457 mm 15 5 8 397 mm 3 4 19 mm Kallista 5 1019455 2 E ...

Page 6: ...ake sure the deck is supported by brick or concrete Install an access panel to allow the pump to be serviced Construct brick or concrete supports Provide a 1 16 2 mm gap between the whirlpool rim and the concrete or brick framing Frame the floor or construct a frame for a raised installation in accordance with the roughing in section of this guide Position the plumbing according to the roughing in...

Page 7: ... material Install an access panel to allow the pump to be serviced Position the plumbing according to the roughing in information Cap the supplies and check for leaks 4 Prepare the Whirlpool We recommend a tiling in bead for straight rimmed whirlpools if one or more sides of the whirlpool contact a wall This bead prevents water from seeping between the whirlpool rim and the wall Follow the instruc...

Page 8: ...mp banding straps from the whirlpool pump NOTE Do not raise the pump higher than it was before you cut the pump banding straps If the pump is raised too high it will not prime properly Make sure the rubber isolation feet are in place To minimize whirlpool noise and vibration be sure the pump is not in direct contact with the whirlpool after the pump banding straps are cut The pump control contains...

Page 9: ...lpool bath control and system have been pre wired at the factory A qualified electrician should make a routine service connection to the junction box Connect service to the junction box The junction box contains blue brown and green with a yellow stripe colored wires Follow local electrical codes Bond in accordance with national and local codes A wiring harness has been pre wired at the factory al...

Page 10: ...re resting directly on the subfloor Ensure that the rubber isolation feet are in place Turn electrical power to the whirlpool on Fill the whirlpool to a level at least 2 50 mm above the top of the highest jet Operate the whirlpool for 5 minutes refer to the Operating Sequence section and check all whirlpool piping connections on the back side for leaks Turn on each of the whirlpool features and ve...

Page 11: ...alant where the tile meets the whirlpool surface Install the faucet trim according to the instructions packed with the trim 12 Clean Up After Installation When cleaning up after installation do not use abrasive cleansers as they may scratch and dull the whirlpool surface If necessary use warm water and a liquid detergent to clean the surface of the whirlpool user keypad and remote control Remove s...

Page 12: ...mote control Press the power icon to turn on the whirlpool The whirlpool will start at medium flow Increase or decrease the water flow by pressing either the up or down arrow icons on the keypad An indicator bar in the center of the keypad shows the water flow volume Adjust each jet for optimum air water mixture Turn the jet trim clockwise to reduce the air flow and counterclockwise to increase th...

Page 13: ...ntative ASR or qualified electrician should correct all electrical problems For warranty service contact your dealer or wholesale distributor Symptoms Probable Causes Recommended Action 1 User keypad does not illuminate when power button is pressed or outer ring is rotated A No power to control A Check wiring and connect power B GFCI or RCD is tripped B Reset the GFCI or RCD C Wiring harness from ...

Page 14: ...p does not work C Replace motor pump D Control does not work D Replace control 7 Pump stops before 18 minutes A GFCI or RCD is tripped A Identify source of fault and correct Reset the GFCI or RCD B Suction is blocked B Remove obstruction C Jets are blocked C Remove blockage D Motor overheated and protection device activated D Check for blockage at suction and or jets Remove blockage and allow moto...

Page 15: ...ll jet 13 Remote control does not work A Batteries improperly installed or dead A Replace batteries B Antenna on wiring harness is damaged B Replace wiring harness C Remote control not programmed correctly C See homeowners guide or service manual D Remote control does not work D Replace remote control E Control does not work E Replace control Kallista 15 1019455 2 E ...

Page 16: ...USA Canada 1 888 4 KALLISTA Fax 1 888 272 3094 kallista com 2019 KALLISTA 1019455 2 E ...

Reviews: