background image

INSTALLATION INSTRUCTIONS

  Volume Control Valve Trim 

1491209-2-

A

6 of 16

Questions? Problems? For additional assistance, please contact KALLISTA’s Customer

Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.

4.  INSTALL THE TRIM

NOTE:

 If installing the P24723-LV trim, proceed to the “For P24723-LV” section below.

 

‰

Place the escutcheon on the wall with the drain notch located downward in the 6 o’clock position.

 

‰

Thread the handle assembly onto the hub of the front plate assembly to secure the escutcheon in place. A 

lever handle should point downward in the 6 o’clock position.

NOTE:

 If the handle does not engage the valve or the escutcheon does not tighten to the wall, replace the 

valve stem adapter with an adapter of appropriate length.

For P24723-LV

 

‰

Thread the adapter ring onto the hub of the front plate assembly.

 

‰

Place the escutcheon on the wall with the drain notch located downward in the 6 o’clock position.

 

‰

Place the handle assembly against the escutcheon by lining up the pins in the handle assembly with the 

holes in the escutcheon. Make sure the handle is pointing down to the 6 o’clock position and the setscrew 

hole is facing down.

 

‰

Verify the setscrew will contact the front angle of the adapter ring. Thread the adapter ring in or out until 

appropriate setscrew contact is achieved.

 

‰

Tighten the setscrew with a hex wrench. Make sure the handle assembly is tight against the escutcheon.

Summary of Contents for P23013-CR

Page 1: ...r additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or kallista com P23013 CR P23013 LV P23123 LV P23223 RK P23223 LV P24113 CR P24113 LV P...

Page 2: ...or performance problems please do not hesitate to contact us at the phone number listed at the bottom of the page BEFORE YOU BEGIN Please read all instructions before you begin Prior to installation...

Page 3: ...y the wall thickness Thin wall 3 16 5 mm to 9 16 14 mm Use the 7 8 22 mm short valve stem adapter stamped 3 on the plaster guard and the 3 8 19 mm screw Standard wall 9 16 14 mm to 1 1 16 27 mm Use th...

Page 4: ...ace the handle assembly over the valve stem adapter Turn the handle counterclockwise until the valve is fully closed The handle should be in the vertical 6 o clock position Remove the handle assembly...

Page 5: ...the valve stem adapter to the valve with the correct length screw as selected in the Install the Valve Stem Adapter section of this guide Align the holes on the front plate assembly and the valve NOT...

Page 6: ...le does not engage the valve or the escutcheon does not tighten to the wall replace the valve stem adapter with an adapter of appropriate length For P24723 LV Thread the adapter ring onto the hub of t...

Page 7: ...ation ou au rendement ne pas h siter nous appeler au num ro de t l phone indiqu en bas de page AVANT DE COMMENCER Lire toutes les instructions avant de commencer Avant l installation d baller la robin...

Page 8: ...liser l adaptateur de la tige de vanne de 7 8 po 22 mm court portant l estampille de 3 po sur le protecteur en pl tre et la vis de 3 8 po 19 mm Mur standard 9 16 po 14 mm 1 1 16 po 27 mm Utiliser l ad...

Page 9: ...sur l adaptateur de la tige de vanne Tourner la poign e dans le sens antihoraire jusqu ce que la vanne soit compl tement ferm e La poign e doit tre en position verticale 6 heures Retirer l ensemble de...

Page 10: ...la tige de vanne sur la vanne avec la vis de longueur correcte tel que s lectionn dans la section Installer l adaptateur de la tige de vanne de ce guide Aligner les trous de la plaque avant et de la...

Page 11: ...n est pas bien serr e contre le mur remplacer l adaptateur de la tige de vanne par un adaptateur de longueur appropri e Pour P24723 LV Enfiler la bague de l adaptateur sur l embo tement de l ensemble...

Page 12: ...con nosotros al n mero de tel fono que se encuentra en la parte inferior de la p gina ANTES DE COMENZAR Lea todas las instrucciones antes de comenzar Antes de la instalaci n desempaque la guarnici n d...

Page 13: ...de 3 16 5 mm a 9 16 14 mm Use el adaptador de v stago de v lvula de 7 8 22 mm corto con un 3 estampado en el protector de yeso y el tornillo de 3 8 19 mm Pared est ndar de 9 16 14 mm a 1 1 16 27 mm U...

Page 14: ...del v stago de la v lvula Gire la manija hacia la izquierda hasta que la v lvula cierre por completo La manija debe estar en la posici n vertical a las 6 en punto en el reloj Retire el ensamblaje de l...

Page 15: ...v lvula con el tornillo de la longitud correcta tal como se seleccion en la secci n Instale el adaptador del v stago de la v lvula en esta gu a Alinee los orificios en el ensamblaje de la placa front...

Page 16: ...la pared cambie el adaptador del v stago de la v lvula por un adaptador de la longitud correcta Con P24723 LV Enrosque el anillo adaptador en el centro de sujeci n del ensamblaje de la placa frontal...

Reviews: