7
3
Kalfire closed gas fires: three safety measures
1. An electronic flame ionisation detector detects the presence of flames.
If the gasfire does not detect a flame, the delivery of gas is cut off for 1 minute. Following
that, the fire will attempt to reignite automatically. If the fire must be switched off
immediately and should not be relit, hold down the / button on the remote control for
around 10 seconds. This ‘emergency stop’ definitively cancels the heat-controlling device,
pre-empting automatic reignition.
2. 24-hour safety
After 3 consecutive automatic ignition attempts without any flame being detected, the
system will be blocked (code A08). In this case, it is possible to use the remote control to try
to unblock the fire a further 2 times before the system is locked for 24 hours (lock-out code
F08). If this occurs, the gasfire cannot be used for 24 hours, a feature designed to ensure
user safety.