KALE FANS BOREAS Series Quick Start Manualline Download Page 17

9.  Customer service

-16-

After-sales service is very important for the stability of the equipment operation, because of this, KALE company always 
offer customers high quality products and perfect after-sales service, at present, we had set up sales and after-sales 
service centers in five major areas across the country to ensure that we can provide users with thoughtful, fast, high 
quality and comprehensive after-sales service, make users feel relieved, without worry.

Product technical support
Combined with fan equipment installation, commissioning and operation process, we provide users with free training 
about the product basic knowledge, use, maintenance technology and equipment related qualifications and certificates, 
to ensure long term stable operation of equipment.
Support can be got through the following ways:
1, log in our company's official website www.kalefans.net, browse to download the latest product technical specification;
2, Contact our company after-sales service department at + 86-18016247962 to get support;
3, Contact corresponding salesman.
Our companies adhering to the customer first and provide the best service for you.

INSTALLATION GUIDE

BOREAS 

31

Motor phase V missing

 

X

X

 

Motor phase V is missing. Check  the phase.

32

Motor phase W missing

 

X

X

 

Motor phase W is missing. Check  the phase.

38

Internal fault

 

X

X

 

Contact local Danfoss  supplier.

44

Earth fault

 

X

X

 

Discharge from output  phases to ground.

47

Control Voltage Fault

 

X

X

 

24 V  DC  may be overloaded.

51

AMA check U

nom

 and I

nom

 

X

 

 

Wrong  setting for  motor  voltage and/or  motor current.

52

AMA low I

nom

 

X

 

 

Motor current is too low. Check  settings.

59

Current limit

X

 

 

 

VLT overload.

63

Mechanical Brake Low

 

X

 

 

Actual motor current  has not exceeded “release brake” current
within “start delay”  time window.

80

Drive Initialised to Default Value

 

X

 

 

All parameter settings  are initialized to default settings.

84

The connection between  drive
and LCP  is  lost

 

 

 

X

No communication between  LCP and  frequency converter

85

Button disabled

 

 

 

X

See parameter group  0-4* 

LCP

86

Copy fail

 

 

 

X

An error  occurred while copying from frequency converter to  LCP or
vice versa.

87

LCP data  invalid

 

 

 

X

Occurs when copying  from LCP if  the LCP contains erroneous data  -
or if no  data was  uploaded  to the LCP.

88

LCP data  not compatible

 

 

 

X

Occurs when copying  from LCP if  data are moved between
frequency converters  with  major differences  in  software versions.

89

Parameter read only

 

 

 

X

Occurs when trying  to write to  a read-only parameter.

90

Parameter database busy

 

 

 

X

LCP and  RS485  connection are trying  to update parameters  simulta-
neously.

91

Parameter value is not valid in  this
mode

 

 

 

X

Occurs when trying  to write an  illegal value to  a parameter.

92

Parameter value exceeds  the
min/max limits

 

 

 

X

Occurs when trying  to set a  value outside the  range.

nw
run

N

ot 

W

hile 

RUN

ning

 

 

 

X

Parameter can only  be changed when  the motor is stopped.

Err. A wrong password  was entered

 

 

 

X

Occurs when using  a wrong password  for changing a  password-
protected parameter.

1)

 These  faults may  be  caused by mains distortions. Installing Danfoss  Line Filter  may  rectify this problem.

No. Description

Warning Alarm

Trip

Lock

Error

Cause  of Problem

Summary of Contents for BOREAS Series

Page 1: ...al Technology Shanghai Corp KaLe Environmental Technology Shanghai Corp Quick installation guide BOREAS Tel 86 18016245385 Fax 021 57685025 Web www kalefans net Email sales kalefans com Origin China K...

Page 2: ...stallation conditions and types 8 3 1 Roof installation requirement 8 3 2 I beam steel structure 9 3 3 Concrete structure 9 3 4 Angle concrete bent structure 9 4 Fan installation procedures 10 5 Speci...

Page 3: ...possesses relatively high cost performance More importantly our products have passed the strict quality inspection and a variety of safety tests and you can rest assured the operation If you have any...

Page 4: ...product for KALEFANS and its coverage can be up to 1600 sq metres The fans are mainly applied in large space such as the plant logistics warehouse supermarket and farm etc 1 1 Product specification t...

Page 5: ...IDE BOREAS 1 Steel structure 6 Winglet of fan blade 2 Safety ring 7 Fan blades 3 Steel structure fastening 8 Turnbuckle and clamps 4 Extension tube 9 Traction steel wire 5 Main body 10 I type safety a...

Page 6: ...F R O M K A L E F A N S HOUR SERVICE HOTLINE Before operating the unit please read the product description carefully and clear obstacles from the regional operation Ensure there is enough distance for...

Page 7: ...h Drywall Screw 17 6 INSTALLATION GUIDE BOREAS Remark Gross weight Volume www kalefans net F R O M K A L E F A N S HOUR SERVICE HOTLINE Before operating the unit please read the product description ca...

Page 8: ...alefans net 2019 KALEFANS No DESCRIPTION 1 Fan Blade 2 Extension Tube 3 Cardan Joint 4 Fastener Packing details 7 Packing specification CASE NO L W Hmm DIMENSION m3 kg 2 3750 415 390 0 61 76 fan blade...

Page 9: ...3 Installation conditions and types spanner Socket wrench screw driver multimeter distance meter screw glue wire cutter gradienter 8 INSTALLATION GUIDE BOREAS 800 MM Minimum distance is 1 1M Minimum d...

Page 10: ...INSTALLATION GUIDE KALE FANS www kalefans net 2019 3 3 Concrete structure 3 4 Angle concrete bent structure 3 2 I beam steel structure 9...

Page 11: ...power line layout 7 traction steel wire position Notice Check the security measures such as seat belts helmets etc climbing equipment tools products and accessories Notice the extension tube is 90 de...

Page 12: ...reen one or yellow one if no yellow green connect one to one according to the color and then wrapped with insulating tape Notice Four steel wires should be isometric symmetrical ensure all points bear...

Page 13: ...parameters had well set before delivery in factory Notice Running for 15 minutes check it whether there is a abnormal sound and steel wire jitter as well as the current within the rated range Notice...

Page 14: ...INSTALLATION GUIDE KALE FANS www kalefans net 2019 5 Control panel and display 13...

Page 15: ...tly prohibit the structural changes or parameter changes of the electrical control box or it will cause equipment damage or personal injury and death accident duo to the improper set In the electrical...

Page 16: ...contents of this manual the Company will not bear any responsibilities 8 1 Explanation of error codes 15 No Description Warning Alarm Trip Lock Error Cause of Problem 2 Live zero error X X Signal on t...

Page 17: ...d 51 AMA check Unom and Inom X Wrong setting for motor voltage and or motor current 52 AMA low Inom X Motor current is too low Check settings 59 Current limit X VLT overload 63 Mechanical Brake Low X...

Page 18: ...keeping 2 Buyer and user themselves dismount or remove the product 3 Force majeure factors lightning earthquake typhoon etc In order to take full advantage of the product s performance and extend its...

Page 19: ...ur products without our permission Failures caused by natural disasters and fires Over the warranty period Other failures caused by non corporate responsibilities The abovementioned services are only...

Reviews: