background image

VIVO VIT

A

 

Installation Instructions

Bathtub Models

D

E

I

F

GB

PRC

7

ALIGNMENT OF THE CASING 

Before the installation of the tub models CENTRO DUO 
OVAL (mod. 127-7/128-7), MEGA DUO OVAL (mod. 184-7), 
CLASSIC DUO OVAL WIDE (mod. 115-7), CONO DUO (mod. 
733-7/734-7/735-7) and VAIO DUO OVAL (mod. 951-7), 
the casing first has to be set up on the tiled floor. 

•  Set up the casing in the intended place.

•  Align the casing.

Align the casing in exactly horizontal position by 
means of a spirit level.

•  Apply a continuous silicone joint (A, approx. 10 mm 

thick) to the bottom openings of the casing, as illus-
trated.

A

CONNECTION OF THE DRAIN AND 

OVERFLOW FITTINGS

WHIRLPOOLS WITH CASING (MOD. xxx-7)

•  To connect the drain and overflow fittings to the local 

sewerage, place the whirlpool with its height-adjustable 
feet on the supplied mounting boards.

Place, e.g., cardboard underneath the mounting 
boards to protect the casing from damage.

•  Carefully place the whirlpool into the casing and check 

the optimum position of the siphon trap connecting 
hose.

ALIGNMENT OF THE WHIRLPOOL

WHIRLPOOL WITH CASING (MOD. xxx-7) 

The height-adjustable feet are preset to the correct height 
in the workshop. Normally it is not necessary to adjust the 
feet.

CENTRO DUO OVAL (mod. 127-7/128-7)
X =  627 mm 

Y = 630 mm

MEGA DUO OVAL (mod. 184-7)
X =  587 mm 

Y = 590 mm

CONO DUO (mod. 733-7/734-7/735-7)
X =  597 mm 

Y = 600 mm

CLASSIC DUO OVAL WIDE (mod. 115-7)/ 
VAIO DUO OVAL (mod. 951-7)
X =  567 mm 

Y = 570 mm