11
3)
Touch the test lead tips together to check if they are
connected normally. The indicator light should turn
green and the buzzer sounds.
4)
Press “
” key to switch to “ ” function.
5)
Connect the probe with both ends of the capacitor in
parallel for measurement.
6)
After the reading stabilizes, record the reading from
the screen.
7)
When the measurement is completed, disconnect
the test leads from the measured object.
WARNING
When measuring capacitance, please disconnect
the power supply and discharge capacitors to
prevent safety hazard.
1)
Long press “ ” key to turn on the power.
2)
Insert the red probe into the “ ” jack and the black
probe into the "COM" jack.
3)
Touch the test lead tips together to check if they are
connected normally. The indicator light should turn
green and the buzzer sounds.
4)
Press “
” key to switch to “
” function.
5)
Connect the red test lead to the positive end of the
diode and the black test lead to the negative end.
Tips:
Generally, the positive end of the diode is the
longer end. If there is no reading, switch the test leads
Diode Test