P a g e |
2 5
P a g e |
2 4
©2018 Kaivac, Inc. All Rights Reserved |
www.kaivac.com
Customer/Technical Support |
1-800-287-1136
4.2 R
ePLacement
(m
onthLy
)
4.3 t
RouBLeshooting
t
iPs
4.0 Maintenance
the following tasks should be performed monthly to keep your system operating at peak performance.
• Poor Vacuum Pickup
1. check squeegee blades. if blades are worn or damaged, replace squeegee Head.
2. clean Float cage.
3. check for leaks in the Vacuum Hose or gasket.
4. check for clogged Vacuum Hose.
5. For battery units, charge may be too low for heavy soils.
6. check to see if float ball was tripped.
• Vacuum Shuts Off Prematurely
1. check Float cage; clean if dirty
2. cleaning chemicals may be producing too much foam. use correct chemicals.
3. battery may need recharged or replaced.
• Other issues? Contact Technical Support
Phone:
united states and canada: 1-800-287-1136
international: 1-513-887-4600
unscrew cuff at end
of Vacuum wand,
remove old squeegee
Head and replace
with new every 6-8
weeks for optimal
performance.
imPOrTANT: if cuff is
removed, ensure brass
ring stays in place.
check for worn squeegee blades.
Worn blades cause streaking and
loss of vacuum suction.
rePlACe iF WOrN
!
email:
[email protected]
For technical support contact Form go to:
https://www.kaivac.com/contactus.php
and choose Technical Support tab.
5.1 P
Roduct
s
Pecifications
5.0 Parts Diagrams and Specifications
Battery Box Specifications
Weight
16.8 lbs. (7,6 kg)
Body Material
Injection Mold Polypropylene
Dimensions (H x W x D)
13.5 x 19.5 x 10 in. (34,3 x 49,5 x 25,4 cm)
Voltage
36V DC
Battery Capacity
20 A-hr
Battery Current
15 A DC
Battery Type
Lithium-Ion
Approx. Run Time BOL (Beginning of Life)
75 to 85 minutes
Approx. Run Time EOL (End of Life)
50 Minutes (discontinue use and take to recycling center)
Battery Box Receptacle
IP67 w/cover (not required for UL)
Run Time Hour Meter
Acts as “odometer for Battery” and runs only when motor switch is ON
Cutoff Voltage (fully discharged)
30V
Charger Specifications
Approx. Charge Time
5.5 hours
Charger Amps
5 Amps
Charge Voltage
42V DC
Charger Voltage
110-240VAC/36VDC (240VAC version only needs correct plug for
wall outlet)
Charging Robustness
No special instructions
Battery Charge Memory
None
Battery Charge Gauge
Yes, LED Indicator
Approx. Charge Cycles
400 @ 100% discharge (500 @ 80% discharge)
Storage/Inventory
Storage & Operation Ambient Temp
32
0
F (0
0
C) to 80
0
F (27
0
C)
Storage & Shipping Charge
40-60% Charge (35-38VDC)
Vacuum Wand Specifications
Body Material
1-piece aluminum;
14 Inch Squeegee Head with Brushes
Vacuum Hose
15’ crush-proof and grease-resistant hose
Cleaning Width
14” with Vacuum Wand. 28” with rear-mounted AutoVac
TM
attachment
Squeegee Head Replacement:
Detachable no tools required
Cleaning Pads
(5) 26” orange and gray wet microfiber pads
Solution Tank Specifications
Solution Tank Capacity
10 Gallons (37,9 l)
Solution Tank Material
Injection Mold Polypropylene
Variable flow Spigot
Yes