1 Stop bit
Even Parity
5.2.4 Maintenance parameters
Press MENU, press MAIN PARA, enter the password, press Enter and Confirm.
MENU
DEFAULT
VALUE
FUNCTION
Oil Filter Run Time (H)
0000
Service of Oil Filter Real Time. When replacing oil
filter it has to be manually reset.
Air/Oil Separator Run
Time (H)
0000
Service of Separator Element Real Time. When
replacing separator it has to be manually reset.
Air Filter Run Time (H)
0000
Service of Air Filter Real Time. When replacing air
filter it has to be manually reset.
Lubricant Run Time (H)
0000
Service of Lubricant Real Time. When replacing oil
it has to be manually reset.
Grease Run Time (H)
0000
Service of Grease Real Time. When greasing it has
to be manually reset.
Oil Filter Max Run Time
(H)
2000
Alarm Prompt Hours. Set to OOOO and function is
disabled
Air/Oil Separator Max
Run Time (H)
2000
Alarm Prompt Hours. Set to OOOO and function is
disabled
Air Filter Max Run Time
(H)
2000
Alarm Prompt Hours. Set to OOOO and function is
disabled
Lubricant Max Run
Time (H)
2000
Alarm Prompt Hours. Set to OOOO and function is
disabled
Grease Max Run Time
(H)
2000
Alarm Prompt Hours. Set to OOOO and function is
disabled
The following alarms will occur from this maintenance menu if set parameters are exceeded:
ALARM
MENU
MESSAGE
Air filter alarm
Digital # 19
AIR BLOCK
Maintenance
AIR TIME END
Oil filter alarm
Digital # 21
OIL BLOCK
Maintenance
OIL TIME END
Separator alarm
Digital # 20
O/A BLOCK
Maintenance
O/A TIME END
Lubricant alarm
Maintenance
LUBE TIME END
Grease alarm
Maintenance
GREASE TIME END
5.2.5 Touch screen calibration