background image

Printed in Germany   0913   000555600900

5

Kaiser
RB 5000 DL
Copy Lighting Unit
5556

ON/OFF

230-240 V, 50 Hz

(or export version 
120 V, 60 Hz)

1

2

max.

45 mm

1

3

4

2

6

Changing lamps and starters

Pull out the mains plug before changing a fluorescent lamp (3) or a starter (4). 

Open the lamp holder (1) by pulling the retainer (2) off the fluorescent lamp, and then folding back
the lamp holder bracket. Hold down the red release button (5), and take the fluorescent lamp (3) up-
ward out of the fitting (6). Put the new fluorescent lamp into the lamp holder (1) first. Then push the
contact pins on the fluorescent lamp into the fitting from above, until they audibly click home. Then
close the lamp holder.       

Starters (4) are taken out of their sockets by turning them anti-clockwise. Fit new startes by turning
them in the opposite direction.  

Important instructions

Please note that it takes approx. 3 minutes before fluorescent lamps have correct colour 
temperature. 
Avoid turning the lamps on and off within very short perids of time as this will reduce the 
service life of the lamps.
Do not cover the ventilation holes of the light troughs during operation.

Spare lamp

:

36 W, 5400 K, colour reproduction index: CRI = 90-100, 

(Art.-No. 5567)

average life: 8000 h (code no. 5567)

Starter

:   

Single, AC 220-240 V, 36 W, e.g. Osram St 111, 4-80 W or Philips S 10, 4-65 W

Right reserved to make technical modifications. 

KAISER FOTOTECHNIK GMBH & CO. KG

Im Krötenteich 2 · 74722 Buchen · Germany
T49(0)6281-4070 · Fax +49(0)6281-40755
www.kaiser-fototechnik.de · [email protected]