Kaise OPZV Series Operation Manual Download Page 12

OPzV Battery Operation Manual

10

Avoid over-charge; otherwise, battery life will shorten. The maximum charging time by constant

voltage of 2.35V/cell and current limited of 0.15C

10

(A) should be not more than 24 hours.

5 Storage

All lead acid batteries experience self-discharge in open circuit. The result is that open circuit

voltage decreases, and the capacity also decreases. During storage please note:

A) The self-discharge rate is related with ambient temperature. The self-discharge rate is

smaller when the ambient temperature is lower, otherwise is larger. The required temperature of
battery’s storage environment is from 5

to 30

. The storage place must be clean, ventilated and

dry;

B) An important parameter in storage is open circuit voltage, which is related with density of

the electrolyte. If the open circuit voltage is lower than 2.08V/cell, or have been stored for long
time, the batteries should be charged to avoid damage caused by self discharge;

Storage temperature

Longest interval

over 30

once 6 months

under 30

once 9 months

C)

All batteries, which are ready to store, should be fully charged before storage. It’s

suggested to record the storage time in the periodic maintenance record and record the time when
another necessary supplemental charge should be made;

D) The quality certificates and packages of VRLA/gel batteries record the latest charge time

of the batteries, next charge time can be calculated according to this charge time.

6 Maintenance

In order to assure service life, the batteries should be correctly inspected and maintained.

6.1 Cleaning

Keep batteries and battery room clean and dry.

Avoiding induce of static electricity during clean of batteries.

Use damp cloth for cleaning, don’t use gasoline, alcohol and other organic solvents.

6.2 Check and maintenance

Perform following routine checks and keep records.

Summary of Contents for OPZV Series

Page 1: ...OPZV SERIES TUBULAR GEL BATTERY OPERATION MANUAL Version 1 1...

Page 2: ...2 3 Working Principle 3 PART TWO OPERATION AND MAINTENANCE 4 1 Operation Condition 4 2 Capacity 4 3 Temperature 5 4 Charge and discharge requirements 7 5 Storage 10 6 Maintenance 10 PART THREE BATTER...

Page 3: ...ction The batteries for replacement should be used as the same as the old ones in model and type Warning Do not smoke or use fire near batteries Warning Do not use any organic cleanser to clean batter...

Page 4: ...l formula active material Valve Made of acid proof aging proof synthetic rubber Flame arrestor With acid proof explosive proof functions 2 Product Specifications Model Nominal Voltage V Capacity Ah 10...

Page 5: ...eparator to set up oxygen cycle principle Battery is full of gel electrolyte inside and A 3 D porous network is formed with framework of SiO2 The net contains electrolyte necessary for battery At init...

Page 6: ...y The capacity can be expressed in Rated Capacity or Actual Capacity The Rated Capacity please sees Table 1 1 The Actual Capacity is the product of the discharge current and the discharge time the uni...

Page 7: ...0 2C 1 80 0 2C I 0 6C 1 75 0 6C I 1 0C 1 70 1C I 2C 1 60 3 Temperature 3 1 Available Capacity vs Ambient Temperature Temperature affects capacity of the battery Fig 3 1 is the available capacity curve...

Page 8: ...y at 25 And temperature compensation coefficient is 3Mv cell Table 3 3 Floating Voltage of VRLA Battery 25 Series Floating voltage V cell OPzV 2 23 0 02 The formula to calculate float voltage at diffe...

Page 9: ...tes performance of VRLA battery is bad it s liable to cause thermal run away when heat accumulates Please improve ventilation and temperature condition when room temperature is high The distances betw...

Page 10: ...ging time reached 16 hours Recharging Procedure 1 Connect the batteries in series with cables or copper bars and make sure that all the screws tightened with each joint then connect the positive of ba...

Page 11: ...capacity if it is still less than 80 of rated capacity then the battery already fails Charging Equipment and Tools No Tool Explanation Purpose 1 Battery Test Equipment or Power System If there is no...

Page 12: ...ge is lower than 2 08V cell or have been stored for long time the batteries should be charged to avoid damage caused by self discharge Storage temperature Longest interval over 30 once 6 months under...

Page 13: ...ound Quarterly Maintenance Yearly Maintenance Items Details Benchmarks Maintenance Items Details Benchmarks Maintenance Float voltage for each battery Measure the voltage of each battery under floatin...

Page 14: ...ow or not compensate according to temperature the battery system will in an insufficient charge state for a long period of time When the electricity is out the battery may not be able to work because...

Page 15: ...me after discharge If the battery is put aside without charge for a long time after discharge it will affect the capacity and life of the battery Because in the negative some large size PbSO4 will be...

Page 16: ...nner wall of the equipment and other batteries should be avoided 2 5 Keep the battery away from heating things such as a transformer 3 Installation and Wiring 3 1 Wrap the metal mounting tool such as...

Page 17: ...lgroup com Tel 51 12 719445 www tempelgroup com Tempel Group en el mundo BARCELONA MADRID VALENCIA BILBAO SEVILLA LISBOA PORTO BUENOS AIRES LIMA SANTIAGO DE CHILE BOGOT SA PAULO M XICO DF CIUDAD DE PA...

Reviews: