For 2 unit type:
Malfunction
Error Code
Indoor unit EEPROM parameter error
E0/EA
Indoor / outdoor units communication error
E1
Indoor fan speed is operating outside of the normal range
E3
Indoor room temperature sensor T1 open circuit or short circuit
E4
Evaporator coil temperature sensor T2 open circuit or short circuit
E5
Communication error between the indoor PCB and display board
Eb
Overload current protection
F0
Outdoor ambient temperature sensor T4 open circuit or short circuit
F1
Condenser coil temperature sensor T3 open circuit or short circuit
F2
Compressor discharge temperature sensor T5 open circuit or short circuit
F3
Outdoor unit EEPROM parameter error
F4
Outdoor fan spe
ed is operating outside of the normal range
F5
IPM malfunction or IGBT over-strong current protection
P0
Over or low voltage protection
P1
High temperature protection of IPM module
P2
Inverter compressor drive error
P4
Mode conflict
--