KWX-24HRDO
Procedure
Illustration
1) Remove the connector for the
compressor (see
CJ_ODU_INV_011
).
2) Pull out the two blue wires connected
with the four way valve (see
CJ_ODU_
INV_011
).
3) Pull out connectors of the condenser
coil temp. sensor(T3),outdoor ambient
temp. sensor(T4) and discharge temp.
sensor(T5) (see
CJ_ODU_INV_011
).
4) Disconnect the electronic expansion
valve wire (see Fig
CJ_ODU_INV_011
).
5) Remove the connector for the DR and
reactor (see Fig
CJ_ODU_INV_011
).
6) Then remove the electronic control box
(see Fig
CJ_ODU_INV_011
).
4-Way Valve
Reactor
DR
Compressor
T3, T4, TP
Electronic Expansion Valve
CJ_ODU_INV_011
Note: This section is for reference only. Actual unit appearance may vary.
Page 54
M
ai
n
te
n
an
ce
a
n
d
D
is
as
se
m
b
ly