1-YEAR LABOR WARRANTY 

 

Kairak warrants that equipment manufactured by Kairak will be free from defects in 
material and workmanship for a period of 1-year beginning 30 days after ship date.  All work 
must be pre -approved by the factory to qualify for reimbursement under this warranty. 
Unapproved labor claims will not be paid. Note: t-stat and time clock adjustments are not 
covered under this warranty. 
 

1-YEAR PARTS WARRANTY 

 
Components such as compressors, fan motors, t-stats (ETC), time clocks, expansion valves, 
etc. shall be warranted for a period of 1-year beginning 30 days after ship date. Note:  
gaskets, filters, cutting boards, driers, sight glasses, and freon are not covered under this 
warranty. Kairak must be informed of the component failure and given the option to ship a 
replacement part or authorize purchase of the part locally by the service contractor. Parts 
utilized for emergency replacement and parts purchased locally by contractor shall be 
reimbursed at cost, an invoice of the purchased part must be supplied with the labor invoice. 
All defective parts must be returned to Kairak C.O.D. via UPS or common carrier. 
 

5-YEAR COMPRESSOR WARRANTY  

 

Compressor manufacturer warrants compressor components for a period of twelve months 
from the serial number manufacture date. Replacement compressors required during this 
period are to be acquired by over the counter exchange at the appropriate wholesaler. Kairak 
will warrant the labor to replace the compressor for the first year only. After the expiration 
of the compressor manufacturer warranty as indicated above, Kairak will warrant 

compressors only for a period not to exceed 4-years from the original start-up date. 

 Labor, tax, 

shipping, and miscellaneous parts will not be included. Please contact our Warranty 
Department for compressor replacement and procedures during this time. 
 
 

PLEASE NOTE: 

Contributing factors that impact refrigeration performance such as fixture doors and or 
drawers being left open, hot products such as soup being placed inside the reach-in box, 
fixture top insert pans being left out, improper equipment maintenance, debris such as plastic 
wrap covering coil openings, food not being removed from drain areas, are all considered 
maintenance and or improper usage will not be covered under warranty.   

 

Kairak Warranty/Service Department – (800) 833-1106 After Hours – (714) 870-9400 

 

500 S. State College Blvd., Fullerton, CA. 92831 

(Phone: 714-870-8661 Fax:  714-870-6473)

 

 

 

 

Summary of Contents for KRES

Page 1: ...Kairak IM ES REV 5 09 06 500 S State College Blvd Fullerton CA 92831 PN 4406010 1 A Div of ITW FEG LLC INSTRUCTION MANUAL KRES Equipment Stands Self Contained and Remote...

Page 2: ...tions include marine or flat top stainless steel back 6 inch casters and drawer locks Some options are not available on all models INSTALLATION Prior to installation test the electrical service to ass...

Page 3: ...LTER Remove louvered panel by lifting up and pulling out entire panel Slide the filter into the tracks located below the compressor compartment Be careful not to catch the filter on sharp edges when i...

Page 4: ...to the bottom of the cabinet with 4 or 6 depending on the model 6 32 x 3 8 phillips head screws Place the condensate evaporator in the heater bracket Slide the heater bracket into the mounting rails P...

Page 5: ...for refrigerant line brazing 50 50 or cold solder is not acceptable For system charge follow remote refrigeration system manufacturer s instructions ELECTRICAL CONNECTIONS Refer to the wiring diagram...

Page 6: ...nge this setting set the pins to desired off times Each pin represents 15 minutes Pins pulled out away from center of time clock represent refrigeration off Pins pushed toward center indicate refriger...

Page 7: ...perature settings are preset at the factory but local conditions may necessitate slight adjustments On self contained refrigerated models the temperature control shown in Fig 5 is located in the compr...

Page 8: ...ated units the temperature control should be set at 37 F with a 3 F differential This display should read between 34 F and 40 F The temperature control setting is locked to avoid unauthorized adjustme...

Page 9: ...used for an extended period of time disconnect the electrical power supply and the drawers to the storage cabinet As soon as the cabinet has warmed to room temperature wipe out the base interior MAIN...

Page 10: ...KAIRAK Page 10 10 IM ES REV 5 09 06 doc5 09 06 Fig 7 Fig 8 Cross Rail Lock Cross Rail Lock 1 on each side of drawer Drawer Module Liner Lock Black Clamping Knob Black Clamping Knob...

Page 11: ...n the back of unit A phillips head screwdriver is required to remove rear access panel Carefully clean dirt and lint from the condenser coil using a vacuum cleaner or soft brush do not use a wire brus...

Page 12: ...ously Door gaskets not sealing properly Condensing unit filter is dirty Evaporator coil is iced up or dirty Prolonged and or frequent door openings or door s ajar Excessive load of warm food placed in...

Page 13: ...to Kairak C O D via UPS or common carrier 5 YEAR COMPRESSOR WARRANTY Compressor manufacturer warrants compressor components for a period of twelve months from the serial number manufacture date Replac...

Reviews: