One pulse: The detector alarms when it detects one pulse.
Two pulses: The detector alarms when it detects two pulses.
Three pulses: The detector alarms when it detects three pulses.
The higher the pulse count is, the lower the sensitivity will be, but high pulse count can reduce false alarm.
3.3. Battery Replacement:
When in low voltage status, detector will send signal to the alarm control, then the user should replace the battery in time.
Remove the bottom cover, and put the new battery in right polarity. (As the picture)
Ⅳ
.Walking Test in Detection Area
1. Set the detector to test mode to perform walking test. Pulse count can be set by PULSE 1, 2, 3.
2. Walk breadthwise from any direction at the remote detection coverage at the speed of
0.75m/s, then the LED indicator blinks for 1 second and alarm triggered. (As the right picture)
3. Test in different direction to confirm the two boundaries of detection. Ensure the detector
rightly points to the central detection zone.
4. The center of detection zone should not uphill inclined. In order to obtain a good detection
range, please adjust the vertical detection range, to ensure the detector is in right position.
5. Perform the walk test again as above when you have adjusted the detection range.
6. When the detector passed the walking test, please adjust the test mode to normal mode
Please don’t invert the detector while installing. Here advice user to have a walk test every week.
V. IX30-Z-Wave Operation
1. Add & Remove
Add
: enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the door sensor
will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s.
Remove
: enter the Exclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the door
sensor will be removed after a period of time.
2.
Association Groups Description
The sensor has 2 associations Inclusion Mode in groups, Lifeline group can support 1 device only, Group 2 can