www.kahnclimatecontrol.co.uk
Installation Instructions
Installation of the Indoor Unit
3
1
2
Location of indoor unit
Good ventilation, away from dust, direct rain and direct sunlight.
A
Keep the air inlet and outlet free from any obstructions.
Keep the height distance between the indoor and outdoor unit within 5m.
If mounted on a wall or suspended from the ceiling ensure they are sturdy enough to bear the weight.
.
Location of outdoor unit
Keep at least 1m away from any electrical appliances.
Do not restrict air flow to the outdoor unit.
Mains power feed is to the outdoor unit - NOT the indoor unit.
If locating the outdoor unit indoors the plenum air extraction box must be used.
void locating equipment close to flammable gas sources.
A firm foundation solid enough to bear the weight of the unit and not cause any shaking.
Remove the electrical control
box cover from the control box
See fig 1
See fig 2
indoor unit
cable connects
to outdoor unit
Cable 1
This cable
goes to the
control box
1 2 3 4
1 2 3 4
5 6 7 8
From control box
Fig 1