 Thank’s for choosing Kahn. Please read this user handbook carefully prior to 

Incorrect use may cause fire, electric shock and the unit falling may result in 

injury or leakage. Contact our designated Kahn service centre on 0333 222 4016 

specialists. The manufacturer shall not assume responsibility for accidents or injury 

caused by incorrect use.

 

This product must not be disposed together with the domestic waste. 

This product has to be disposed at an authorised place for recycling 

of electrical and electronic appliances.

Kahn Climate Control 

LITTLE BOY 

user handbook

installing and keep it for further reference.

 Thank’s for choosing Kahn. Please read this user handbook carefully prior to 

Incorrect use may cause fire, electric shock and the unit falling may result in 

injury or leakage. Contact our designated Kahn service centre on 0333 222 4016 

specialists. The manufacturer shall not assume responsibility for accidents or injury 

caused by incorrect use.

 

This product must not be disposed together with the domestic waste. 

This product has to be disposed at an authorised place for recycling 

of electrical and electronic appliances.

Kahn Climate Control 

ATOM 

user handbook

installing and keep it for further reference.

Summary of Contents for Little boy

Page 1: ...centre on 0333 222 4016 specialists The manufacturer shall not assume responsibility for accidents or injury caused by incorrect use This product must not be disposed together with the domestic waste This product has to be disposed at an authorised place for recycling of electrical and electronic appliances Kahn Climate Control LITTLE BOY user handbook installing and keep it for further reference ...

Page 2: ...N U R O O D N I O Attention Indoor Unit Outdoor Unit Front view To mount install the outdoor unit indoors the optional Plenum box MUST be used The maximum length of the connecting pipe if rubber is 9m The maximum distance between indoor unit and outdoor unit is 30m if using copper piping Please refer to our youtube channel which offers video advice and guidance for installation Find us on search f...

Page 3: ...cation of outdoor unit Keep at least 1m away from any electrical appliances Do not restrict air flow to the outdoor unit Mains power feed is to the outdoor unit NOT the indoor unit If locating the outdoor unit indoors the plenum air extraction box must be used void locating equipment close to flammable gas sources A firm foundation solid enough to bear the weight of the unit and not cause any shak...

Page 4: ...placed or extended be sure to use identical diameter Please refer to the wiring diagram located on the reverse of the cover plate of wiring terminals inside the evaporation unit On the outdoor unit the wiring diagram is fixed to the inside of cover plate which protects the wiring terminal block to the right side of the condenser R W B Indoor unit Indoor unit Remote controller cable Earth Ground th...

Page 5: ...e tightening the screws Earth wire must be connected firmly 3 Replace the wiring terminal covering plate and secure firmly with mounting screws Installation of the Outdoor Unit Connecting pipe Fig 3 Air outlet L 1 2 3 N Outdoor unit wiring terminal Interconnecting cale between indoor and outdoor units Unscrew and remove the removable panel Indoor unit Outdoor unit Earth Brown Blue Black not suppli...

Page 6: ...nection finger tightening initially to avoid risk of cross threading Remove both brass end caps from the two valves on the outdoor unit this will reveal an allen key connection on both valves Turning anticlockwise first half unscew the small liquid port valve you will hear refrigerant gas passing through the small pipe this will occur for up to 6 seconds Repeat the above process for the larger gas...

Page 7: ...to collect the refrigerant when moving the indoor unit or the outdoor unit 1 Press the push button switch on the circuit board once The LED on the circuit board starts flashing one second ON one se cond OFF This indicates the start of PUMP DOWN operation When the switch is pressed while the compressor is in operation PUMP DOWN operation starts automatically When the switch is pressed while the com...

Page 8: ...ired controller guide UNIT ON NIGHT DAY NIGHT DAY SET SET 900 UP TO 100 H M L H M L NIGHT DAY FAN HEAT COOL FAN HEAT COOL 0 0 0 0 1 1 1 1 Please refer to our youtube channel which offers video advice and guidance for maintenance Find us on search for Kahn Climate Control or use the QR code ...