Electrical Wiring
Connections
1 Remove the wiring terminal cover plate (on the side of the outdoor unit), connect mains lead
4 Once completed perform a final check to ensure integrity of cabling between the indoor
and the outdoor unit
2 Loosen the fixing screws on each of the wiring terminals and feed the power communications,
and earth cables through their respective fixing clips before tightening the screws.
Earth wire must be connected firmly.
3 Replace the wiring terminal covering plate and secure firmly with mounting screws.
6
Installation of the Outdoor Unit
Connecting pipe
Drain hose
Air inlet
Air outlet
Drain opening
L
1 2 3
N
Live
(Brown)
Neutral
(Blue)
Earth
(Yellow/Green)
Earth
(Yellow/Green)
Live
(Brown)
Neutral (Blue)
Communications (Black)
Outdoor unit wiring terminal
Interconnecting cale between
indoor and outdoor units
Indoor unit
Outdoor unit
Earth
Brown
Blue
Black
(not supplied) to right hand side of terminal block by unscrewing the mounting screws.