10.17.1 Cleaning the solenoid valve
Fig. 36 Cleaning the solenoid valve condensate drain
1
Solenoid valve
2
Screw
3
Coil
4
O-ring
5
Spring
6
Solenoid core
7
Arrow showing flow direction
8
Shut-off valve
1. Close the shut-off valve upstream of the condensate drain.
2. Undo the screw and carefully remove the coil.
3. Clean the solenoid core.
If the spring and O-ring are damaged or worn they must be replaced.
4. Reassemble the valve.