background image

4

  |  Kaden Owner’s Manual

Read Safety Precautions Before Installation

Thank you for purchasing this air conditioner. This manual will provide you with information on how to operate, maintain, and 
troubleshoot your air conditioner. Following the instructions will ensure the proper function and extended lifespan of your unit. 

Please pay attention to the following signs:

1.  Safety Precautions

This symbol indicates that ignoring instructions may cause death or serious injury.

This symbol indicates that ignoring instruction may cause moderate injury to your person,  
or damage to your unit or other property.

  WARNING

•  Ask an authorised technician to install this air conditioner. Inappropriate installation may cause water leakage, electric shock, 

or fire.

•  The warranty will be voided if the unit is not installed by professionals.

•  If abnormal situation arises (like burning smell), turn off the power supply and call an authorised technician for instructions  

to avoid electric shock, fire or injury.

•  Do not

 let the indoor unit or the remote control get wet. It may cause electric shock or fire.

•  Do not

 insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating  

at high speeds.

•  Do not

 use a flammable spray such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.

  CAUTION

•  Do not

 touch the air outlet while the swing flap is in motion. Fingers might get caught or the unit may break down.

•  Do not

 inspect the unit by yourself. Ask an authorised technician to perform the inspection.

•  To prevent product deterioration, do not use the air conditioner for preservation purposes (storage of food, plants, animals, 

works of art, etc.).

•  Do not

 touch the evaporator coils inside the indoor unit. The evaporator coils are sharp and may cause injury.

•  Do not

 operate the air conditioner with wet hands. It may cause electric shock.

•  Do not

 place items that might be affected by moisture damage under the indoor unit. Condensation can occur at a relative 

humidity of 80%.

•  Do not

 expose heat-producing appliances to cold air or place them under the indoor unit. This may cause incomplete 

combustion or deformation of the unit due to the heat.

•  After long periods of usage, check the indoor unit to see if anything is damaged. If the indoor unit is damaged, it may fall and 

cause injury.

•  If the air conditioner is used together with other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.

•  Do not

 climb onto or place objects on top of the outdoor unit.

Summary of Contents for KD Series

Page 1: ...Kaden Owner s Manual 1 Owner s Manual DUCTED AIR CONDITIONER KD36 KD42 KD48 KD60 KD Series...

Page 2: ......

Page 3: ...and Major Functions 6 3 Care and Maintenance 8 4 Troubleshooting 9 5 Disposal Guidelines 13 Important note Read this manual carefully before installing or operating your new air conditioning unit Mak...

Page 4: ...is may cause injury since the fan may be rotating at high speeds Do not use a ammable spray such as hair spray lacquer or paint near the unit This may cause re or combustion CAUTION Do not touch the a...

Page 5: ...if they have been given instruction on how to properly and safely operate the system Do not operate the air conditioner in a wet room e g bathroom or laundry room This can cause electrical shock and c...

Page 6: ...e 17 C 32 C 0 C 30 C 17 C 32 C Outdoor Temperature 15 C 50 C 15 C 24 C 0 C 50 C Default Setting When the air conditioner restarts after a power failure it will default to the factory settings AUTO mod...

Page 7: ...o keep cool or warm air in the room Do not place objects near the air inlet and outlet of the unit This will reduce the ef ciency of the unit Set a timer and use the built in SLEEP ECONOMY mode if app...

Page 8: ...an electrical re Please make sure the drain hose is set up according to the instructions Failure to do so could cause leakage and result in personal property damage re and electric shock Make sure tha...

Page 9: ...nit will start operating again The set temperature has been reached at which point the unit turns off the compressor The unit will resume operating when the temperature uctuates again The indoor unit...

Page 10: ...noises The unit will make different sounds based on its current operating mode Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use w...

Page 11: ...let or outlet of either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit...

Page 12: ...11 Overload protection 1 On F0 12 Outdoor temperature sensor error 2 On F1 13 Outdoor condenser pipe sensor error 3 On F2 14 Discharge air temperature sensor error 4 On F3 15 Outdoor EEPROM Electrica...

Page 13: ...ehold waste or unsorted municipal waste When disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility Sell the a...

Page 14: ...14 Kaden Owner s Manual Notes...

Page 15: ...Kaden Owner s Manual 15 Notes...

Page 16: ...16 Kaden Owner s Manual kadenair com au...