LMHT-SA
PREVENTATIVE MAINTENANCE
CHECK LIST
HOW OFTEN
CHECK
REFERENCE
1 Year
1.
Check anode in receiver tank (if
applicable).
Drain tank – remove anode by
unscrewing anode plug on the receiver
tank end. If over 60% eaten away,
replace.
2.
Clean gauge glass when required.
Disassemble and pull clean cloth
through glass with cleaning wire.
3.
Drain tank and flush to remove
residue.
Remove drain plug in the bottom of
tank and flush. Replace plug
afterwards.
4.
Pull internal mechanism and inspect
for wear on pins and linkage and for
buildup on the float.
Remove cap screws in top flange and
remove internal mechanism and
inspect.
CAUTION:
Before performing any of the above maintenance checks, shut off all steam and
condensate lines connected to the unit.