10 .
KABI Mobile Diesel Oil Tanks
V. TT250/425/600 TANK MAINTENANCE
Table 1 below shows the scheme of the operation procedure for TT250/425/600 .
Tab.1. The list of standard maintenance activities for TT250/425/600
Activity
Minimum
frequency
Date
Date
Date
Date
Check and clean the pump filter
Every 6 months
Check and clean the flow meter filter (in the case
of heavy pollution of filters also check and clean
the measuring chamber)
Every 6 months
Check the flow meter battery condition
Every 6 months
Calibrate the flow meter
Every 2 months
or 40000 L
Check and clean the suction strainer
Every 6 months
Clean the tank and components of its equipment
(pump, flow meter, cables, housing, etc .)
Every 6 months
Check the operation of the pumping system
(tightness, efficiency, nozzle, etc .)
Every 6 months
Check the condition of the tank and its equip-
ment for completeness and mechanical damage
Every 6 months
Check the electrical installation of the pump
(correctness, connection, protection devices)
Every 6 months
Lubricate the flap lock
Every 6 months
9
Correctly
%
Incorrectly
NOTE: Activities included in the table above should be performed immediately if a malfunction is noted on
TT250/425/600 .
Detailed information on the operation and maintenance of the devices of the distribution system (pump, flow
meter, etc .) are included in the operating and maintenance manual of the manufacturer of these devices .