Troubleshooting
8.1
Fault table
Fault
Possible cause
Remedy
No length measurement is be-
ing done
The measuring wheel sticks.
Free up the measuring wheel.
The measuring wheel has no
contact.
The measuring wheel may still
be locked. Unlock.
The measurement is inaccu-
rate
The measuring wheel is worn
out.
Replace the measuring wheel.
The vertical guide is open.
Close the vertical guide and in-
crease resistance, if necessary.
Tab. 10 Fault table MESSBOI 25