6.9 Setting the end-of-tape sensor
Place the sensor so that the red dot from the light of the
sensor is close to the core of the adhesive tape roll.
1. Loosen the fastening screw for the sensor using a
suitable tool.
2. Move the sensor to the required position.
3. Tighten the fastening screws for the sensor using a
suitable tool.
The position of the sensor must be such that, when the end
of the tape is indicated, there are still enough layers of tape around the core for the active taping
process to be ended and the cable set to be completely taped.
The setting of the sensor is thus critically dependent on the length of the cable set being taped.
Setting the tape width
It is also necessary to adapt the setup of the end-of-tape
sensor according to its operating distance.
The operating distance of the sensor can be adjusted using
the cross-head screw:
-
Anticlockwise turning - operating distance decreases
-
Clockwise turning - operating distance increases
The green lamp indicates that the sensor is ready for use.
The orange lamp will light up whenever the sensor
responds to the presence of an object.
Set the sensor so that the orange lamp is active only when the tape
is in the vicinity of the red dot of light.