SAFLOK Door Unit Inspection Criteria

Appearance

• 

Finish is free of blemishes or scratches that would distract from lock appearance

• 

Lock body and under plate (if used) are mounted straight on the door

• 

Door scalp is mounted straight and flush with the door edge

• 

Jamb strike is mounted straight and is flush with the jamb face

• 

Correction of minor blemishes on the door jamb are the responsibility of the property’s maintenance department

Lock Function

• 

Knob or lever rotates and moves freely

• 

Lever is horizontal to floor when at rest position

• 

Dead bolt extends fully and retracts without binding (door open)

• 

Lock latch and dead bolt engage jamb strike plate freely

• 

Anti-pick latch when depressed (door open)

• 

Anti-pick latch is depressed when contact is made with the strike plate (door closed)

Electronics/Keycards

• 

Green light flashes when the proper keycard is used

• 

Green light is flashing when the lever is operated

• 

Green light continues to flash for a five-second cycle

• 

Yellow light flashes 12 times when the dead bolt is extended and a guest/hotel keycard is used

• 

All keycards function to the specifications of the properties key design

Door function

• 

Door closes and latches with little or no interference

• 

Dead bolt extends fully through the strike plate without interference (door closed)

• 

Spacing between door edge and inside door jamb does not exceed 3/16” (door closed)

Note:

 If bumpers or other seals are added after strike plate installation and causes alignment and latch problems, it 

is the property’s responsibility to correct this condition. This note generally applies to new construction or new door 
installation

Questions?

 Call Customer Service at 800.999.6213 and select option 3. For online assistance, visit support.saflok.com.

FCC and IC Warnings:

 This device complies with part 15 of the FCC Rules. Operation is subject to the following two 

conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s 
authority to operate the equipment.

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following 
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, 
including interference that may cause undesired operation of the device.

© SAFLOK, all rights reserved.

INS_MTRFID_2_12

Summary of Contents for Saflok MT RFID

Page 1: ...e sole use of the addressee s so named Any misuse of this confidential information contained herein may result in legal action by Computerized Security Systems dba SAFLOK and its parent company Optional Communication Modules I S Chassis Assembly I S Escutcheon 30320 H Color Assy Strike Buttons A29030 Color Screw Pack MT Universal 1 3 4 2 1 4 Mortise see Mortise Options table 51190 Color Outside Fr...

Page 2: ... MT drill fixture position and clamp the fixture on the door Do NOT drill the four holes for the card reader as illustrated in Fig 1 below instead drill the hole shown in Fig 2 The fixture has two positioning posts that rest inside the mortise establishing the proper backset for the trim When the fixture is clamped its surfaces should be parallel with the door surfaces and door edges Not all holes...

Page 3: ...pulled as the mortise is inserted into the pocket 4 Attach the mortise front plate to the door using the two mortise screws 12 x 1 1 4 screws for wood doors 12 24 x 3 8 screws for metal doors Be sure that the screws are fully tightened Important DO NOT leave the mortise screws loose The screws must be fully tightened before the trim is installed If you must leave the mortise loose to install the t...

Page 4: ...m edge of the rectangular hole with a piece of tape SAFLOK spacer plates will be required for doors less than 1 3 4 thick Be sure ribbon and power wire are completely pulled through the lock housing to ensure neither are pinched between the door and the lock chassis 3 Route the ribbon cable and power wire through the rectangular hole in the inside trim This hole is located above printed circuit bo...

Page 5: ...tises or at the bottom 6 00 position for standard mortises see Fig 4 Position dead bolt spindle assembly into cam assembly The retaining ring should rest on the switch cam when fully inserted the proper positioning of the cam will allow the door to be opened when the dead bolt is retracted and block entry when the dead bolt is thrown for privacy except when emergency keycards are used Important As...

Page 6: ...erminal The programming port is located in the bottom of the outside lock trim Test the functioning of the lock as discussed in the following section and in the programming manual before closing the door When the construction key is used the green and red LEDs will blink together indicating that the lock s time and date are not set 15 For locks installed in exterior applications After programming ...

Page 7: ...me and date not set use the Hand held and Quantum RFID nine times simultaneously LPI probe to reset or for 5 seconds Yellow LED flashes 12 times Dead bolt is thrown or switch cam is not properly aligned Yellow LED flashes two times Keycard not allowed OR keycard cancelled by new keycard Red and green LEDs flash Low battery contact the SAFLOK service department alternately nine times Yellow and red...

Page 8: ...ons of the properties key design Door function Door closes and latches with little or no interference Dead bolt extends fully through the strike plate without interference door closed Spacing between door edge and inside door jamb does not exceed 3 16 door closed Note If bumpers or other seals are added after strike plate installation and causes alignment and latch problems it is the property s re...