Kaba Saflok MT RFID Installation Instructions Manual Download Page 2

© SAFLOK, all rights reserved.

INS_MTRFID_2_12

MT

TM

 RFID Installation Instructions

Pg 2 of 8

Preparing the door and door frame

1.  Prepare the door using the MT RFID installation template or drill fixture. The door edge prep is a standard,  

full-mortise prep for a 1-1/4” x 8” front plate (1” x 8” and 1” x 7-3/4” custom front plates are optional).  
The door surface holes and mortise are customized for the SAFLOK trim.

 

Important:

 Some holes are only on the inside surface of the door. See the door prep template.

 

 

•  For new construction installations, the door manufacturer may prepare the door using the 

 

 

  installation template.

 

 

•  For retrofit installations, remove the existing hardware and confirm that the existing door edge 

 

 

  prep is appropriate for the SAFLOK mortise lock. 

 

Drill fixture:

 If you are using a SAFLOK MT drill fixture, position and clamp the fixture on the door. Do NOT drill  

the four holes for the card reader as illustrated in Fig. 1 below; instead, drill the hole shown in Fig. 2. The fixture  
has two positioning posts that rest inside the mortise, establishing the proper backset for the trim. When the  
fixture is clamped, its surfaces should be parallel with the door surfaces and door edges. Not all holes go through 
the door (refer to the template). Notch the material on the inside surface for easier routing of the motor wire.  
After machining, remove any debris from the mortise and cutouts.

2.  Prepare the door frame using the template and install the strike plate using the screws provided
 

(12 x 1-1/2 screws for wood frames, 12-24 x 3/8 screws for metal frames).

STAND

 

ADB

 

4.44

 

.30

 

Ø

 

 

  

 

 

 

Note: The hole shown above is not located on
the drill fixture. Use these measurements to
locate the hole.

Do not use these four holes

(Always left of lock center 
when viewed from outside)

.88 THRU

C of lock

L

Fig. 1

Fig. 2

Summary of Contents for Saflok MT RFID

Page 1: ...e sole use of the addressee s so named Any misuse of this confidential information contained herein may result in legal action by Computerized Security Systems dba SAFLOK and its parent company Optional Communication Modules I S Chassis Assembly I S Escutcheon 30320 H Color Assy Strike Buttons A29030 Color Screw Pack MT Universal 1 3 4 2 1 4 Mortise see Mortise Options table 51190 Color Outside Fr...

Page 2: ... MT drill fixture position and clamp the fixture on the door Do NOT drill the four holes for the card reader as illustrated in Fig 1 below instead drill the hole shown in Fig 2 The fixture has two positioning posts that rest inside the mortise establishing the proper backset for the trim When the fixture is clamped its surfaces should be parallel with the door surfaces and door edges Not all holes...

Page 3: ...pulled as the mortise is inserted into the pocket 4 Attach the mortise front plate to the door using the two mortise screws 12 x 1 1 4 screws for wood doors 12 24 x 3 8 screws for metal doors Be sure that the screws are fully tightened Important DO NOT leave the mortise screws loose The screws must be fully tightened before the trim is installed If you must leave the mortise loose to install the t...

Page 4: ...m edge of the rectangular hole with a piece of tape SAFLOK spacer plates will be required for doors less than 1 3 4 thick Be sure ribbon and power wire are completely pulled through the lock housing to ensure neither are pinched between the door and the lock chassis 3 Route the ribbon cable and power wire through the rectangular hole in the inside trim This hole is located above printed circuit bo...

Page 5: ...tises or at the bottom 6 00 position for standard mortises see Fig 4 Position dead bolt spindle assembly into cam assembly The retaining ring should rest on the switch cam when fully inserted the proper positioning of the cam will allow the door to be opened when the dead bolt is retracted and block entry when the dead bolt is thrown for privacy except when emergency keycards are used Important As...

Page 6: ...erminal The programming port is located in the bottom of the outside lock trim Test the functioning of the lock as discussed in the following section and in the programming manual before closing the door When the construction key is used the green and red LEDs will blink together indicating that the lock s time and date are not set 15 For locks installed in exterior applications After programming ...

Page 7: ...me and date not set use the Hand held and Quantum RFID nine times simultaneously LPI probe to reset or for 5 seconds Yellow LED flashes 12 times Dead bolt is thrown or switch cam is not properly aligned Yellow LED flashes two times Keycard not allowed OR keycard cancelled by new keycard Red and green LEDs flash Low battery contact the SAFLOK service department alternately nine times Yellow and red...

Page 8: ...ons of the properties key design Door function Door closes and latches with little or no interference Dead bolt extends fully through the strike plate without interference door closed Spacing between door edge and inside door jamb does not exceed 3 16 door closed Note If bumpers or other seals are added after strike plate installation and causes alignment and latch problems it is the property s re...