RAC Model 3.5 with KIM Swipe Reader
6
Controller (A) to KIM
Swipe Reader (B)
Connections
Controller
KIM Swipe Reader
JP3-1
Red
JP3-2
Black
JP3-3
Orange
JP3-4
Green
JP3-5
Purple
JP3-6
Brown
JP3-7
Blue
JP3-8
Yellow
JP3-9
N.C. (White)
JP3-10
N.C.
JP3-11
N.C.
JP3-12
N.C.
J2-3
Shield
Table 1
Controller to RPI*
Controller
RPI*
Signal
J4-1
J1-1
E
J4-2
J1-2
TX
J4-3
J1-3
RX
J4-4
J1-4
GND
Table 2
* RPI – Remote Programming Interface
Status LEDs
LED
Description
D21
Relay 0
D20
Access
D19
Programming
D18
Initialization
D23
Unused
D24
Unused
D26
Functionality 1
D27
Functionality 2
Table 3
Figure 3.
Access Delay Select DIP Switch Bank
Access Delay DIP Switch Settings
(S2)
CFG#
4
3
2
1
SEC
1
ON
ON
ON
ON
8
2
ON
ON
ON
OFF
1
3
ON
ON
OFF
ON
3
4
ON
ON
OFF
OFF
5
5
ON
OFF
ON
ON
10
6
ON
OFF
ON
OFF
15
7
ON
OFF
OFF
ON
20
8
ON
OFF
OFF
OFF
25
9
OFF
ON
ON
ON
30
10
OFF
ON
ON
OFF
35
11
OFF
ON
OFF
ON
40
12
OFF
ON
OFF
OFF
50
13
OFF
OFF
ON
ON
60
14
OFF
OFF
ON
OFF
90
15
OFF
OFF
OFF
ON
120
16
OFF
OFF
OFF
OFF
REINIT
Example of S2 Settings
Delay times can vary from 1 second to 120 seconds.
Choose the delay required from Table 6, then set the
DIP switches accordingly. For example, with DIP switch-
es 4, 3, 2, 1 in the ON, OFF, ON, OFF positions respec-
tively, a delay of 15 seconds is set.
Do not use CFG #16 because this setting is only
used for reinitializing the controller.
Table 4
TB1 Power Connections
Terminal Symbol Description
1
Earth Ground
2
N
Neutral
3
AC Live
Table 5