4 Cabling
Connectors to be plugged in as follows:
Marking on the lock case
Cable connection for
Marked
„input unit“
6-pole connecting cable to the electronic input system
Marked
„power“
4-pole operating voltage (battery compartment)
Confusion of the connecting cables does not produce any damage of the electronic system of the lock. The lock will not be
operable in this case and must be connected correctly in accordance with the circuit diagram.
Always press the latching clip of the plug against the plug housing for disconnecting the plugs and sockets. Do not pull out
plug reaching for the plug housing or the cable.
Make sure that the connecting cable is not damaged during installation. Cable sheathing or flexible leads must not be
impaired, otherwise hazard of a short circuit. Protect the cable by protective hoses or plastic pipes in the area of transition
and moving parts. Make sure also that the cable is not buckled or installed in pinched condition.
5 Adjustment /final check
The bolt is correctly adjusted when the bar dolly after slight clockwise turning jumps back by resilience to its horizontal
home position. After turning of the bar up to stop position, the bar dolly may remain in stop position.
Make sure when opening the lock that the bar dolly can be moved smoothly.
Function of the lock to be tested in accordance with the operating instructions. Also check the mechanical opening by the