Kaba Mauer 82132 Mounting Instructions Download Page 2

 
 
 
 

 

 

 

 

 

Stand 15.02.2016 

Seite 2 von 10 

Mounting Instructions 

82132/33 Code-Combi B with Plastic Control Unit 

 

 

Any variation of the lock or key may result in functional trouble and must  better not be done. All claims under guarantee 
and warranty will expire in this case. 

 

 

Lock fastening: Use of M6 steel socket head cap screws or BSW ¼" steel bolts. The length of engagement must 
correspond to the applicable standards considering the thickness of the lock of 30 mm and the screwing height of the lock 
case of 24 mm. 

 

Fastening screws: minimum property class 4.8 and maximum property class 8.8. 

 

 

Screws to be secured either by lock washer, flat spring, tooth lock washer, fan type lock washer considering the diameter 
(d1) or to be cemented 

 

 

Screw tightening moment: minimum 5 Nm and maximum 6 Nm. 

 

 

The bolt must be floating in installed condition.  

 

 

Perfect function of the lock and of any additional connected or triggered systems (e.g. boltworks) must be warranted and 
checked by specialists during installation of the lock.  

 

 

The lock must be mounted in closed condition (bolt extended). 

 

 

The opening (cable gland) in the door of the secure storage unit may not be greater than 100 sq. mm (see mounting 
drawings on Page 5 and following). 

 

 

The lock is designed for installation in secure storage units made of steel. Installation in storage units consisting of other 
material e.g. plastic is not allowed. 

 

 

Do not apply any kind of force (e.g. hammer blows) for screw fitting and adjustment of the lock. 

 

 

Lock to be installed covered and so as to prevent opening by boring. 

 

 

The two way key must be insertable without jamming. 

 

  It  is  recommended,  that  unauthorized  persons  have  no  access  to  security  sensitive  parts  of  the  lock,  also  the  door  of  the 

safe, where the lock is installed, is open. 

 

 

Use of the Kaba Mauer key guide (see Fig. 1) is recommended. Considering DIN 2768-mH, the keyhole in the door of the 
secure storage unit should be dimensioned accordingly (see Fig. 1).  

 
 
 
 
 
 

 
 
 

 

Fig. 1: Key Guide 86101 

 

 

In cases where the Kaba Mauer key guide or key carrier guide are not used, the maximum cross sectional area of the 
keyhole in the door of the secure storage unit and/or the lock armour plating may not exceed the dimensions given in Fig. 2 
considering DIN 2768-mH. All dimensions deviating from these specifications are to be coordinated separately with the 
certification bodies (test houses). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 2: Maximum cross sectional area of keyhole 

Code-Combi B 

X (mm) 

Y (mm) 

71161 

17 

12.5 

7,

5

m

ax

.

O

12

ma

x.

max. X

max. Y

 

R

4

R4

O

8

4,

2

4,

2

5,

9

5,

9

25,5

12,75

 

Summary of Contents for 82132

Page 1: ...loc batteries only Low quality batteries may cause oxidation which results in a functional failure of the lock Avoid residual crystalline moisture in the cabinet e g from varnishing so as to prevent attack of the electrical contacts Make sure that ingress of dirt or detergents e g remaining fillers or cold cleaners is prevented Do not grease oil the lock or key 2 Mounting instructions for lock and...

Page 2: ...an 100 sq mm see mounting drawings on Page 5 and following The lock is designed for installation in secure storage units made of steel Installation in storage units consisting of other material e g plastic is not allowed Do not apply any kind of force e g hammer blows for screw fitting and adjustment of the lock Lock to be installed covered and so as to prevent opening by boring The two way key mu...

Page 3: ...ning of the boltwork via two M4 threads on the front end of the bolt head Optional fastening of the boltwork via a drift pin in the bolt head The bolt was according to EN1300 with a permanent load of 2 5 N over 10 000 cycles tested These load should not be exceeded permanently 3 Mounting of the control unit Two possibilities are available for fastening of the control unit 1 from the inner side of ...

Page 4: ...not pull out plug reaching for the plug housing or the cable Make sure that the connecting cable is not damaged during installation Cable sheathing or flexible leads must not be impaired otherwise hazard of a short circuit Protect the cable by protective hoses or plastic pipes in the area of transition and moving parts Make sure also that the cable is not buckled or installed in pinched condition ...

Page 5: ... 1 82132 33 Code Combi B with plastic control unit 98851 0001 Lock mounting position Control unit mounting position 3 2 6 1 1 1 3 9 6 1 Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O Separate battery compartment Keyhole in lock Cable gland 10 mm or Ø 11 25 0 05 mm 97 59 23 5 59 83 5 33 Door penetrations ...

Page 6: ...3 Code Combi B with plastic control unit 98851 0002 Lock mounting position Control unit mounting position Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O 6 1 3 2 1 1 3 9 6 1 97 59 23 5 59 33 83 5 Cable gland 10 mm or Ø 11 25 0 05 mm Separate battery compartment Keyhole in lock Door penetrations ...

Page 7: ...Code Combi B with plastic control unit 98852 0001 Lock mounting position Control unit mounting position Depth of battery compartment appprox 60 mm 43 24 5 34 5 O 3 2 3 2 O 9 1 1 3 6 1 3 2 6 1 59 59 97 97 23 5 23 5 85 Cable gland 10 mm or Ø 11 25 0 05 mm Separate battery compartment Keyhole in lock Door penetrations ...

Page 8: ...ode Combi B with plastic control unit 98852 0002 Lock mounting position Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O 6 1 3 2 9 1 1 3 6 1 23 5 23 5 97 97 59 59 90 Cable gland 10 mm or Ø 11 25 mm 0 05 mm Separate battery compartment Keyhole in lock Control unit mounting position Door penetrations ...

Page 9: ...ode Combi B with plastic control unit 98852 0003 Lock mounting position 3 2 6 1 1 1 3 9 6 1 Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O 23 5 23 5 97 97 59 59 90 Cable gland 10 mm or Ø 11 25 mm 0 05 mm Separate battery compartment Keyhole in lock Control unit mounting position Door penetrations ...

Page 10: ...Code Combi B with plastic control unit 98852 0004 Lock mounting position Depth of battery compartment approx 60 mm 43 24 5 34 5 O 3 2 3 2 O 6 1 3 2 1 1 3 9 6 1 23 5 23 5 97 97 59 59 90 Separate battery compartment Keyhole in lock Control unit mounting position Cable gland 10 mm or Ø 11 25 mm 0 05 mm Door penetrations ...