4
O
PEN
AND
C
LOSE
THE
X-09 (
FACTORY
COMBINATION
)
If you have not read the section on “Dialing the X-09”, it is important that
you do so before proceeding.
Note:
The lock is shipped preset to operate in the Single Combination Mode with
a
Default Factory Combination
of
50-25-50
.
TO OPEN THE LOCK (using the Factory Combination):
CW=ClockWise;
CCW=CounterClockWise
1. Dial
left
(CCW) until lock is “powered”. The lock is considered “powered” when numbers
appear on the LCD display screen.
2. Continue dialing
left
(CCW) to the fi rst number of the factory combination (50).
Stop on 50 and pause briefl y.
3. Dial
right
(CW) to the second number of the factory combination ( 25). Stop on 25
and pause briefl y.
4. Dial
left
(CCW) to the third number in the factory combination (50).
Stop on 50 and pause briefl y.
5. Dial
right
(CW). After
OP
with a right arrow (
OP
en right) is displayed, continue dialing to
the right to retract the lock bolt.
Note:
If at any time the dial remains stationary for more than 40 seconds, the
lock will power down (LCD will go blank), requiring the operator to redial the entire
combination.
TO CLOSE THE LOCK:
1. Turn Dial to the
left
(CCW) a minimum of one complete revolution to extend the bolt.
2. Turn Dial to the right (CW) a minimum of one complete revolution to ensure that it
is
locked.
Note:
The Dial should turn freely in either direction without catching or binding
when the bolt is extended and the lock is closed.
Practice opening and closing the lock several times with the preset factory combination
before you set a new combination.