background image

6 Support

K6-Team

Ihn. Ingrid Rüth

B.-v.-Linsenmann-Str. 7
72108 Rottenburg
Germany

http://www.k6-team.de 
E-Mail: [email protected]

Please don't put old devices into the garbage, return it to us.
After the EU FAQ list the devices which are intended specially to the application in means of 

transportation are excluded from the range of application of the RoHS directive and with it from § 5 
ElektroG.

Of course the K6 Bt is soldered lead-free.

K6 Bt 

2

 Manual

www.k6-team.de

7

Warning:

K6 Bt may loose NMEA data sets. Never rely 
entirely on the indication of your end device. 
Airspace observation is essential!

Summary of Contents for K6Bt2

Page 1: ...t GPS device e g flight recorder flarm variometer and a bluetooth enabled device e g PDA Smartphone Tablet or PC It is possible to send data in both directions using several baud rates The baud rate can be configured automatically manually by jumpers or with a compatible software To prevent unauthorized access the connection is password protected K6 Bt 2 Manual www k6 team de 1 ...

Page 2: ...evice has to be switched on the red LED begins with blinking and glows out after a few seconds details see chapter 2 2 4 Connect the bluetooth device PDA smartphone Tablet or PC over bluetooth with the K6 Bt activate bluetooth and search for new bluetooth devices detailed action depends on device and operation system The bluetooth ID of K6 Bt begins with K6BT The pre set identification and is prin...

Page 3: ...ondition of the K6 Bt permanent light after turning on ready for configuration changes after 4 seconds red LED blinks automatic baud rate identification is enabled and baud rate is not found yet red LED out baud rate found or constant setting green LED blinks no bluetooth connection established yet green LED flashes bluetooth connection established 2 3 Jumpers Remove the screws and open the housin...

Page 4: ...tomatically to detect the baud rate of the connected device Detection of the baud rate is only possible when the connected device sends NMEA 0183 conforming data with at least one sentence per second After the power on the K6 Bt searches for the correct baud rate indicated by double blinking of the red LED If the correct baud rate is found the LED stays off The set baud rate is maintained until th...

Page 5: ...or any other terminal program Use the following configuration for the terminal program to connect with the K6 Bt baud rate 115200 baud data bits 8 parity none stop bits 1 flow control none After applying the power supply to the K6 Bt the string ikkk one second pause has to be entered in the terminal program within 4 seconds while the red LED is continuously on The K6 Bt shows its main menu kkk K6 ...

Page 6: ...umber may differ from device to device Consult the manual of your bluetooth device Start the program which should receive data from the K6 Bt and choose the serial port assigned to the bluetooth connection in the settings dialogue 5 Specification dimensions ca 72x50x28mm connection ports 2x RJ45 connection ports with IGC compliant pinout Power supply 5 to 15V by one of the connection ports configu...

Page 7: ...e EU FAQ list the devices which are intended specially to the application in means of transportation are excluded from the range of application of the RoHS directive and with it from 5 ElektroG Of course the K6 Bt is soldered lead free K6 Bt 2 Manual www k6 team de 7 Warning K6 Bt may loose NMEA data sets Never rely entirely on the indication of your end device Airspace observation is essential ...

Reviews: