INSTALLATION 

 

CAUTION:

 Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, 

unplug the pump and allow time for it to cool after periods of extended use. 

1. Connecting a 3/4 in. garden hose  

 

Attach a 1 in. female adaptor (B) to the pump discharge. 

 

Attach a garden hose with a 3/4 in. garden hose thread (not included) to the adaptor. 

 

NOTE:

 Be sure the 3/4 in. garden hose thread connector has a rubber gasket to 

minimize water leaks. 

NOTE: 

The  larger  the  inside  diameter  and  the  shorter  the  length  of  hose,  the  less 

pressure that is lost (or the larger the flow rate). 

 
 
 

2. Connecting a 1-1/4 in. hose kit  

If you would prefer to use a 1-1/4 in. hose kit (not included) in order to pump water away 

more quickly. 

 

Attach the adaptor (B) to the pump (A) discharge. 

 

Securely attach the hose kit (not included) to the adaptor (B).  

 

WARNING: 

Secure  the  discharge  hose  before  plugging  in  the  pump.  An  unsecured 

discharge hose may 

“whip” possibly causing personal injury, and/or property damage. 

 

 OPERATION 

1. Plugging in the pump 

 

Place the pump on a solid base in flooded area or any place that you 

would like to remove water. Plug the pump into a 115 volt GFCI power 

outlet

 

WARNING: 

Do not handle the pump or pump motor with wet hands or when 

standing on a wet or damp surface, or in water. 

NOTE:

 Place upright on a solid base.

 

NOTE: 

The pump must be standing in at least 1 in. (25.4 mm) of water before 

you start it.  

2. Operating the pump 

 

Allow the pump to run and monitor its progress.

 

 

Unplug the pump when it has removed water down to 

approximately 1/ 4in. (6.4 mm). 

 

Remove the pump and hose from the location when finished 

pumping. The hose still has water that can drain back through the 

pump. Remove remaining water with a squeegee, mop, sponge, 

towel, wet/dry vacuum, etc. 

CAUTION: 

Do not run the pump dry. Operating the pump without water will cause damage to the seals and will cause 

the pump to fail, thereby voiding the pump’s warranty.

 

Summary of Contents for UTM01602K

Page 1: ...ATIC UTILITY PUMP Questions problems missing parts Before returning to the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 2019 Copyright GP Enterprises Co Ltd Rev 11 06 19 Model UTM01602K UTM02502K ...

Page 2: ... must be directly inserted into a properly installed and grounded 3 prong grounding type receptacle Do not use this pump with a 2 prong wall outlet Replace the 2 prong outlet with a properly grounded 3 prong receptacle a GFCI outlet installed in accordance with the National Electrical Code and local codes and ordinances All wiring should be performed by a qualified electrician 10 Protect the elect...

Page 3: ... pump is designed for water removal applications Pump water only with this pump It can drain or remove water from the following pits sinks window wells basements swimming pool covers boats low spot in yards or other flooded areas This pump has not been tested or approved for use in swimming pools or in salt water marine areas This pump is not designed to function as a permanently installed sump pu...

Page 4: ...ptor B WARNING Secure the discharge hose before plugging in the pump An unsecured discharge hose may whip possibly causing personal injury and or property damage OPERATION 1 Plugging in the pump Place the pump on a solid base in flooded area or any place that you would like to remove water Plug the pump into a 115 volt GFCI power outlet WARNING Do not handle the pump or pump motor with wet hands o...

Page 5: ...lugin the power cord restarting the pump CAUTION This hole is for anti airlock purposes Leakage of air or water is NORMAL DO NOT BLOCK THIS HOLE CARE AND CLEANING CAUTION Always use the handle to lift the pump Never use the power cord to lift the pump To avoid skin burns unplug the pump and allow time for it to cool after periods of extended use Do Do Not When the power is disconnected inspect the...

Page 6: ...es not cover Use of the product in a non residential application improper installation and or maintenance of the product damage due to misuse acts of God nature vandalism or other acts beyond control of K2 owner s acts or omissions use outside the country in which the product was initially purchased and resale of the product by the original owner This warranty does not cover pick up delivery trans...

Page 7: ...upport call 1 844 242 2475 7 of consequential damages so the above exclusion may not apply to you This warranty gives you specific rights You may also have others that vary from state to state Thank you for choosing an K2 product ...

Reviews: