PERFORMANCE 

 

Model 

HP 

GPH of Water @ Total Feet Of Lift

 

Max. Lift 

0 ft. 

5 ft. 

10 ft. 

15 ft.  

20 ft.  

25 ft. 

UTM01602K 

1/6 

1500 

1400 

1300 

1100 

750 

300 

27 ft. 

UTM02502K 

1/3 

2200 

2000 

1750 

1500 

1200 

800 

31 ft. 

 

SAFETY INSTRUCTIONS 

 

1. 

Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the 

presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion 

or fire, resulting in property damage, serious personal injury, and/or death. 

2. 

ALWAYS disconnect the power to the pump before servicing. 

3. 

Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not 

disassemble the motor housing. 

4. 

Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water 

before disconnect the power. 

5. 

Release all pressure and drain all water from the system before servicing any component. 

6. 

Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing 

personal injury, and/or property damage. 

7. 

Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening 

safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension 

cord to power this pump is not permitted. 

8. 

Wear safety goggles at all times when working with pumps. 

9. 

This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor 

cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must 

be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this 

pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI 

outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should 

be performed by a qualified electrician. 

10.  Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use 

damaged or worn cords. 

11.  Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO 

USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death. 

12.  Ensure that the electrical circuit to the pump is protected by a 10 Amp fuse or circuit breaker. 

13.  Do not lift the pump by the power cord. 

14.  Know the pump and its applications, limitations, and potential hazards. 

15.  Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping 

the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature 

failure. 

16.  Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and 

debris. Disconnect the pump from the power supply before inspecting. 

17.  Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all 

Occupational Safety and Health Administration (OSHA) guidelines must be followed. 

18.  The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset 

itself once the motor cools down and an acceptable temperature has been reached. The pump may start 

unexpectedly if it is plugged in. 

19.  Ensure the electrical power source is adequate for the requirements of the pump. 

Summary of Contents for UTM01602K

Page 1: ...ATIC UTILITY PUMP Questions problems missing parts Before returning to the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 2019 Copyright GP Enterprises Co Ltd Rev 11 06 19 Model UTM01602K UTM02502K ...

Page 2: ... must be directly inserted into a properly installed and grounded 3 prong grounding type receptacle Do not use this pump with a 2 prong wall outlet Replace the 2 prong outlet with a properly grounded 3 prong receptacle a GFCI outlet installed in accordance with the National Electrical Code and local codes and ordinances All wiring should be performed by a qualified electrician 10 Protect the elect...

Page 3: ... pump is designed for water removal applications Pump water only with this pump It can drain or remove water from the following pits sinks window wells basements swimming pool covers boats low spot in yards or other flooded areas This pump has not been tested or approved for use in swimming pools or in salt water marine areas This pump is not designed to function as a permanently installed sump pu...

Page 4: ...ptor B WARNING Secure the discharge hose before plugging in the pump An unsecured discharge hose may whip possibly causing personal injury and or property damage OPERATION 1 Plugging in the pump Place the pump on a solid base in flooded area or any place that you would like to remove water Plug the pump into a 115 volt GFCI power outlet WARNING Do not handle the pump or pump motor with wet hands o...

Page 5: ...lugin the power cord restarting the pump CAUTION This hole is for anti airlock purposes Leakage of air or water is NORMAL DO NOT BLOCK THIS HOLE CARE AND CLEANING CAUTION Always use the handle to lift the pump Never use the power cord to lift the pump To avoid skin burns unplug the pump and allow time for it to cool after periods of extended use Do Do Not When the power is disconnected inspect the...

Page 6: ...es not cover Use of the product in a non residential application improper installation and or maintenance of the product damage due to misuse acts of God nature vandalism or other acts beyond control of K2 owner s acts or omissions use outside the country in which the product was initially purchased and resale of the product by the original owner This warranty does not cover pick up delivery trans...

Page 7: ...upport call 1 844 242 2475 7 of consequential damages so the above exclusion may not apply to you This warranty gives you specific rights You may also have others that vary from state to state Thank you for choosing an K2 product ...

Reviews: