K203/K205ULT Operating Manual

Indicator light status description

Symbol

Set

E2H

E2P

Erd

Status

ON

OFF

ON

OFF

FLASH

ON

OFF

FLASH

ON

OFF

ON

ON

ON

ON

OFF

Meaning

Parameter setting

Status of temperature measuring and controlling

High temperature compressor work

High temperature compressor stop

High temperature compresso time delay 

Low-temperature compressor work in non-forced refrigeration mode 

Low temperature compressor is closed in non-forced refrigeration mode 

Forced refrigeration mode

Capillary heating starts

Capillary heating is closed 

High temperature alarm of secondary system condenser

High temperature protection of secondary system condenser 

Door open alarm 

Grid power supply anomaly 

Normal power supply 

Parameters

4

Temperature parameter setting

Summary of Contents for K203ULT

Page 1: ...parameters may damage the unit or void your warranty Please contact K2 before attempting to change advanced parameters Unfamiliar with the operation of a controller Use the video tutorials on our web...

Page 2: ...adjustments and maintenance must be performed by qualified service personnel Do not use this appliance for other than its intended use Do not cover the front grille or block the rear air entry by plac...

Page 3: ...ay to prevent any overflow Ventilation All models must have clear and unobstructed ventilation from the entire surface area of the front grille Temperature Controller 3 SET RST Enter a parameter setti...

Page 4: ...ressor stop High temperature compresso time delay Low temperature compressor work in non forced refrigeration mode Low temperature compressor is closed in non forced refrigeration mode Forced refriger...

Page 5: ...logger 15 0 15 0 0 C9 Condenser probe calibration High temp compressor loop 15 0 15 0 0 C10 Ambient temp probe calibration 15 0 15 0 0 C11 High temp evaporator probe calibration 15 0 15 0 0 C13 The Mi...

Page 6: ...K203 K205ULT Operating Manual Product Description 5...

Page 7: ...K203 K205ULT Operating Manual Maintenance 6 Alarm Code...

Page 8: ...ntact us via our chat feature at www k2sci com 2 Email support k2sci com 3 Call 800 218 7613 When storing vaccines you may be required to preform a field validation test A NIST callibrated external da...

Page 9: ...f cabinet C13 50 0 40 C15 Maximum temp of high temp evaporator when low temp compressor turned off C7 10 0 12 H1 The cycle time of capillary heating wire 1 300 108 H2 The working time of capillary hea...