10 For Professional Technical Support call 1-844-242-2475
5. PUMP TO PRESSURE TANK AND TO HOUSE CONNECTION
Notes: The pump must be within 4’ of the tank to prevent switch chatter. Check the tank pre charge on a yearly basis
Pre-Charge Tank Connection
1. Most pressure tanks will have a 1in. inlet elbow on the
bottom. Connect to this elbow with a
1in. PVC MPT×S
Male Adapter
and a short piece of
1in.PVC rigid
Pipe
. (Fig. 1)
2. Cement a
1in.PVC 90-Degress S×S Elbow
. (Fig. 2)
3. Cement a
1in.PVC rigid Pipe
into elbow then cement
a
1in.×3/4in.PVC Reducing Male Adapter
. (Fig. 3)
4. Cement a 3/4in.PVC rigid Pipe into a 3/4in.CPVC CTC
Socket Tee Fitting. Cement 3/4in. PVC MPT×S Male
Adapter into 3/4in.PVC rigid Pipe that connect with a
3/4in. PVC FPT×FPT Union .(Fig. 4)
5. Make the connection to the house plumbing. From the
tee, install pipe and
3/4in.Slip×Slip Ball Valve
(optional). (Fig. 5)
6. Install a
3/4in. PVC MPT×S Male Adapter
to the
outlet port of the pressure control valve at the top of
the pump. (Fig. 6)
7. Cement a short
3/4in.PVC rigid Pipe
and
3/4in.PVC
90-Degress S×S Elbow
. (Fig. 7)