background image

 

12                                                                                                                   For Professional Technical Support call 1-844-242-2475 

 

 

, also can adjust speed by 

and

,when press 

,automatic recording speed and enter the set 

period 2,and so on. The first time period can be set to a maximum of 0:00-23:59. The second time period can be set as 
the maximum time period (stop time of the first time period-23:59). Time periods 3 and 4 are turned off by default and 

can  be  turned  on  by  either 

  or

 .When  the  settings  are  complete,  wait  10  seconds  for  the  system  to 

automatically save the settings. Example 1: The first time period is 8:00-23:59, the second time period is 23:59-23:59, 
the third time period is off, and the fourth time period is 00:00-03:00. At this time, the pump will run from 8am to 3am the 
next day.   

Press 

 in manual or automatic mode to toggle the display of each set period. 

When the fault code is displayed, press 

 to reset the fault. 

5. Close/turn on the LCD backlight 

Press 

to turn on/off the LCD backing. 

6. Fault code description 

 Communication failure. 

Please check whether the connection line between the display board (upper board) and the drive board (lower board) 
is loose. 

 Supply voltage error. 

The normal power supply voltage is 230V±10%,please check whether the power supply voltage is normal. 

 Locked-rotor protection. 

Please check whether the motor is blocked 

:  Motor open phase. 

Check whether the motor connection is normal. 

: Drive overheating. 

 

CARE AND CLEANING 

 

Pump should only be serviced by qualified personnel. For best results, use only genuine factory parts. Be sure to 
prime pump before starting. 

WARNING

: Risk of explosion. Before beginning pump service. 

1. Stop pump before proceeding. 
2. Close gate valves in suction and discharge pipes. 
3. Release all pressure from pump and piping system. 
 

WARNING

: Risk of electric shock. Can shock, burn or kill. Disconnect power before working on pump or motor. 

When using factory authorized parts, no lubrication or regular maintenance is needed beyond reasonable care and 
periodic cleaning of the strainer basket. 
If shaft seal is worn or damaged, repair as follows: 
 

Summary of Contents for PPV10001SPK

Page 1: ... MANUAL VARIABLE SPEED POOL PUMP Questions problems missing parts Before returning to the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 www K2pumps com Copyright 2021 GP Enterprises Co Ltd K2Man 32 Rev 2 18 21 ...

Page 2: ...e warranty ATTEMPTING TO USE A DAMAGED PUMP can result in property damage serious personal injury and or death 9 WARNING The pump should be connected to a GFCI outlet protected with a15 amp 230V fuse or circuit breaker 10 WARNING Fire and burn hazard Motors run at high temperatures Do not allow leaves debris or foreign matter to collect around the pump motor Allow the motor to cool before handling...

Page 3: ...otor cools down and an acceptable temperature has been reached The pump may start unexpectedly if it is plugged in 22 IMPORTANT Ensure the electrical power source is adequate for the requirements of the pump 23 IMPORTANT This pump is made of high strength corrosion resistant materials It will provide trouble free service for a long time when properly installed maintained and used However inadequat...

Page 4: ...ti entrapment Cover As needed SPECIFICATIONS Power supply 230V 60 HZ 15 Amp Circuit Liquid temp range 32 to 100 F 0 38 C Discharge size 1 1 2 in NPT thread with adaptor INSTALLATION Only qualified licensed personnel should install pump and wiring The pump mount must be located away from corrosive or flammable chemicals THREADED CONNECTIONS Use only PTFE tape or equivalent on threaded plumbing conn...

Page 5: ...p with one to two additional layers of tape and remake the connection NOTICE Support all piping connected to pump Fittings Fittings restrict flow for best efficiency use the fewest number of possible fittings Avoid fittings which could cause an air trap Pool fittings must conform to International Association of Plumbing and Mechanical Officials IAPMO standards Use only non entrapping suction fitti...

Page 6: ...ips and will not re set have a qualified electrician inspect and repair electrical system Verify that supply voltage matches the nameplate voltage Incorrect voltage can cause fire or seriously damage motor and voids warranty Voltage Voltage at motor must be within 10 of the motor nameplate rated voltage or motor may overheat causing overload tripping and reduced component life If voltage does not ...

Page 7: ... to pump amp load If unsure consult a licensed electrician A Ground Fault Circuit Interrupter GFCI is required in the circuit For size of GFCI required and test procedures for GFCI please see manufacturer s instructions Table l Recommended Fusing Data Motor HP Branch Fuse Rating Amps Max Load Amps Voltage Hz Phase Service to Motor Distance in Ft m 0 300 0 30 AWG Wire Size mm2 1 15 3 3 230 60 1 14 ...

Page 8: ... suction and discharge valves are opened If the pump is located above the normal pool water level remove ring and trap assembly and fill trap and pump with water Clean and inspect O ring then reinstall on trap cover Replace trap cover assembly on trap then rotate clockwise to tighten cover NOTICE Tighten ring and cover assembly by hand do not use tools Pump priming time will depend on the vertical...

Page 9: ...60 water solution to protect pump to 50 F 46 C NOTICE Allowing pump to freeze will damage pump and void warranty NOTICE Use only non toxic antifreeze Do not use automotive antifreeze It is highly toxic and may damage plastic components in the system Operation of Control Panel This series of swimming pool pumps are equipped with human machine interface which can display the current time pump start ...

Page 10: ...de the default startup time is high speed 3500RPM for 5 minutes After 5 minutes the startup time will be automatically switched to the speed set by the customer In manual mode the user controls the start and stop of the pump by pressing the start and stop button and the speed can be passed through the panel three buttons to switch can also go through button to adjust the speed press the or button ...

Page 11: ...working time and speed In the setting mode after setting the current time it will automatically enter the setting time period 1 mode At this time you can set the start time and stop time of the pump as well as the running speed When in starts flashing the time can be adjusted through and press to confirm and so on after when set the start time and stop time start flashing at this time for the firs...

Page 12: ...off the LCD backing 6 Fault code description Communication failure Please check whether the connection line between the display board upper board and the drive board lower board is loose Supply voltage error The normal power supply voltage is 230V 10 please check whether the power supply voltage is normal Locked rotor protection Please check whether the motor is blocked Motor open phase Check whet...

Page 13: ...ce down on flat surface and tap out ceramic seat 9 Clean seal cavity in seal plate and clean motor shaft Pump Reassembly Installing New Seal 1 Ceramic seat must be clean and free of dirt grease dust etc Wet outer edge with small amount of liquid detergent press ceramic seat into seal plate cavity firmly and squarely with finger pressure 2 If ceramic seat will not locate properly remove it place fa...

Page 14: ... is then clean trap and strainer 2 Make sure the impeller is not clogged The impeller and diffuser are worn 3 Impeller and diffuser may be worn If so order replacement parts For more information call customer service The pump is incorrect for this installation 4 The pump may be trying to push too high a column of water If so a higher head pump is needed The pump is experiencing electrical issues T...

Page 15: ...er pick up delivery transportation or house calls However if you mail your product to a K2 Sales and Service Center for warranty service cost of shipping will be paid one way This warranty does not apply to products purchased outside of the United States including its territories and possessions outside of U S Military Exchange and outside of Canada This warranty does not cover products purchased ...

Page 16: ......

Page 17: ...IO BOMBA DE VELOCIDAD VARIABLE PARA PISCINAS Preguntas problemas piezas faltantes Antes de regresar a la tienda comuníquese con el servicio de atención al cliente de K2 de 8 a m a 6 p m hora del este EST de lunes a viernes 1 844 242 2475 www K2pumps com ...

Page 18: ...on interruptor de falla a tierra GFCI protegido con un fusible o disyuntor de 15 amperios 230 V 10 ADVERTENCIA Peligro de incendio y quemaduras Los motores funcionan a altas temperaturas No permita que se acumulen hojas residuos o materiales extraños alrededor del motor de la bomba Deje que el motor se enfríe antes de manipularlo 11 PRECAUCIÓN Conozca la bomba y sus usos limitaciones y peligros po...

Page 19: ...chufada 22 IMPORTANTE Asegúrese de que la fuente de alimentación eléctrica sea adecuada para los requisitos de la bomba 23 IMPORTANTE Esta bomba está hecha de materiales de alta resistencia y resistentes a la corrosión Proporcionará un funcionamiento sin problemas durante mucho tiempo si se instala mantiene y utiliza correctamente Sin embargo la bomba puede fallar si la alimentación eléctrica a la...

Page 20: ...apamiento certificada por IAPMO Según sea necesario ESPECIFICACIONES Fuente de alimentación Circuito de 230 V 60 Hz 15 A Rango de temperatura del líquido 32 F a 100 F 0 C a 38 C Tamaño de descarga 1 1 2 pulg NPT con adaptador INSTALACIÓN Solo el personal calificado y autorizado debe instalar la bomba y el cableado El soporte de la bomba debe estar ubicado lejos de productos químicos corrosivos o i...

Page 21: ...O Apoye todas las tuberías conectadas a la bomba Accesorios Los accesorios restringen el flujo Para obtener la mejor eficiencia utilice la menor cantidad posible de accesorios pero al menos dos salidas de succión Evite accesorios que puedan causar una trampa de aire Los accesorios para piscinas deben cumplir con los estándares de la Asociación Internacional de Funcionarios de Plomería y Mecánica I...

Page 22: ...e el voltaje de suministro con el voltaje de la placa de características Un voltaje incorrecto puede provocar un incendio o dañar seriamente el motor y anular la garantía Si tiene dudas consulte a un electricista autorizado ADVERTENCIA riesgo de explosión No ponga a tierra hacia una línea de suministro de gas Voltaje El voltaje en el motor no debe estar más del 10 por encima o por debajo del volta...

Page 23: ...onsulte a un electricista autorizado Se requiere un interruptor de falla a tierra Ground Fault Circuit Interrupter GFCI en el circuito Para conocer el tamaño del GFCI requerido y sus procedimientos de prueba consulte las instrucciones del fabricante Tabla l Datos de fusibles recomendados HP del motor Amperios nominales del fusible de derivación Amperios de carga máxima Voltaje Hz Fase Servicio al ...

Page 24: ...un sistema de succión inundado desatornille y retire la cubierta de la trampa llene la trampa y la bomba con agua No lubrique la junta tórica de la cubierta de la trampa La junta tórica del equipo original contiene un lubricante interno permanente AVISO si reemplaza la junta tórica por una junta tórica sin lubricación interna es posible que deba aplicar un lubricante a base de silicona Limpie e in...

Page 25: ...a y la tubería cuando espere temperaturas bajo cero o cuando vaya a almacenar la bomba por mucho tiempo consulte Drenaje de la bomba Mantenga el motor seco y cubierto durante el almacenamiento Para evitar problemas de condensación corrosión no cubra la bomba con plástico Para instalaciones al aire libre desprotegidas 1 Envuelva todo el sistema en un recinto a prueba de intemperie 2 Para evitar dañ...

Page 26: ...minada la velocidad es de 3500 RPM de alta velocidad durante 5 minutos Después de los 5 minutos la hora de arranque cambiará automáticamente a la velocidad establecida por el cliente En el modo manual el usuario controla el arranque y la detención de la bomba presionando el botón de encendido y apagado y la velocidad se puede cambiar a través de los tres botones o ajustar a través de los botones o...

Page 27: ...velocidad En el modo de configuración después de configurar la hora actual se ingresará automáticamente al modo de configuración del período 1 En este momento puede configurar la hora de arranque y de detención de la bomba así como la velocidad de funcionamiento Cuando en empieza a parpadear el tiempo se puede ajustar con los botones y y se debe presionar para confirmar así sucesivamente hasta est...

Page 28: ...go de falla La comunicación falló Verifique si está suelta la línea de conexión entre la placa de la pantalla placa superior y la de transmisión placa inferior Error de voltaje de suministro El voltaje normal de la fuente de alimentación es de 230V 10 verifique si el voltaje de la fuente de alimentación es normal Protección del motor bloqueado Verifique si el motor está bloqueado Fase abierta del ...

Page 29: ...e una superficie plana y extraiga el asiento de cerámica con un golpe suave 10 Limpie la cavidad del sello en la placa de sellado y el eje del motor Montaje de la bomba instalación de un sello nuevo 1 El asiento de cerámica debe estar limpio y libre de suciedad grasa polvo etc Moje el borde exterior con una pequeña cantidad de detergente líquido presione el asiento de cerámica en la cavidad de la ...

Page 30: ...dete desgastado Asegúrese de que la trampa de succión no esté obstruida si es así limpie la trampa y el cestillo Asegúrese de que el rodete no esté obstruido siga las instrucciones en Retiro del sello viejo revise el rodete para ver si está obstruido siga las instrucciones en Instalación de un sello nuevo para volver a ensamblar El rodete y el difusor pueden estar gastados De ser así llame al serv...

Page 31: ...in embargo si usted manda su producto por correo al departamento de ventas y servicios de K2 para servicios que cubre la garantía el costo del envío será pagado únicamente de ida Esta garantía no se aplica a productos comprados fuera de los Estados Unidos incluyendo sus territorios y posesiones fuera del Intercambio Militar de los Estados Unidos y fuera de Canadá Esta garantía no cubre productos c...

Page 32: ......