Fault
Reason
Remedy
Does not switch
No Power
Check power
Faulty signal line
Check signal line
Faulty electronic Module
Replace Module
Density of liquid too low
Set density to > 0.5 at electronic insert
Fork encrusted
Clean fork
Fork corroded
Exchange fork and process connection
Contacts welded together (after
short-circuit)
Replace Module; put fuse in contact circuit
Switches
incorrectly
Min- / Max– fail-safe mode set
wrong
Set correct mode at electronic insert
Thick heavy foam, very turbulent
conditions, foaming liquid
Mount Resonator Switch in a bypass line
Sporadic faulty
switching
Extreme RFI
Use shielded cable
Extreme vibration
Decouple, damp, turn fork 90°
Water in housing
Screw cover and cable gland tight
Output overloaded
Reduce load: (Cable) capacitance