OWN-003 Model BDI Owner’s Manual – Blender Dispenser with Ice
10
5.4.1.2 Spray or wipe the interior surface of the ice hopper with a mild
soapy solution. Allow this solution to remain in contact with the
ice hopper surfaces for at least five minutes.
5.4.1.3 Slowly pour or spray clean, hot water over the surfaces of the ice
hopper to rinse the soapy solution away. It is very import to pour
slowly as the rinse water will empty into the blend station and then
down the main drain. Overflowing the blend station can cause
blender motor failure. The rinse water will mostly run down the
drain of the unit but some will go into the empty blender jar (watch
so that it does not overflow and empty as needed).
5.4.1.4 Gently pour or spray the sanitizing solution over the surfaces of the
ice hopper. Remember that some sanitizer manufacturers require
their sanitizer to remain in contact with the sanitized object for a
specific amount of time before rinsing or removing. Refer to your
manufacturer’s instructions before rinsing.
5.4.1.5 Rinse the ice hopper surfaces with clean, hot water following step
5.4.1.3 above.
5.4.2
B
LEND
S
TATION
:
5.4.2.1 Remove the blender jar from the blender station (empty if needed).
5.4.2.2 Using a mild soapy solution, wipe down all surfaces of the blend
station. Excess water will drain through the drain opening located
at the back of the unit.
5.4.2.3 Use clear, hot water to rinse the surfaces of the blend station. A
handheld spray bottle will work best.
5.4.2.4 To sanitize the surfaces of the blend station either spray or wipe
the surfaces of the blend station with the sanitizing solution.
5.4.2.5 Remove the blend station door by opening the door and gently
lifting it off of the hinges (do not loose the small plastic washers).
Wash the door in the sink and allow to air dry.
5.4.2.6 Use clear, hot water to rinse the sanitizing solution off of the
surfaces of the blend station.
5.4.2.7 Dry any water off of the blender motor area and replace the
blender door.
5.4.3
D
RAIN
H
OSE
:
5.4.3.1 After sanitizing the ice hopper and blend station, the internal drain
tube should be fairly well cleaned so it is not necessary to run
sanitizer down the internal tube again.
5.4.3.2 Remove the drain tube from the back of the machine.
5.4.3.3 Slowly pour sanitizer solution down the tube. It is not necessary to
rinse the drain tube.
5.4.4 P
RODUCT
T
UBES
:
there are two options to sanitize product lines. The first
is to use the sanitizing cycle built in to the machine, the second is a
simpler method using the JUICE button. You may use either one
depending on preference; the beginning steps are the same.
5.4.4.1 Disconnect all product bags from the product lines and place the
bags in the refrigerator.