K-RAIN MANUFACTURING CORP.
1640 Australian Avenue
Riviera Beach, FL 33404 USA
PH: 561.844.1002 / 1.800.735.7246
FAX: 561.842.9493
www.krain.com
© K-RAIN Manufacturing Corp.
Part Number: 16005103 Rev. 11
ADJUSTING THE LEFT (VARIABLE)
SIDE OF THE ARC
INCREASING THE ARC
Insert the (A) end of the Key into the arc set
adjustment slot (M). While holding the nozzle turret
(I) at the right start, turn the Key clockwise. Each
full 360° turn of the Key will increase the arc 90°.
Adjust to any arc between 40° and 360°. The Key
will stop turning, or there will be ratcheting noise,
when the maximum arc of 360° has been reached.
DECREASING THE ARC
Insert the (A) end of the Key into the arc set
adjustment slot (M). While holding the nozzle turret
(I) at the right start, turn the Key counter-clockwise.
Each full 360° turn of the Key will decrease the
arc 90°. Adjust to any arc between 40° and 360°.
The Key will stop turning, or there will be a
ratcheting noise, when the minimum arc of 40°
has been reached.
INSTALL AND BURY
Do not use pipe dope. Thread the sprinkler on the pipe.
Bury the sprinkler flush on the same watering zone.
NOTE:
Gear driven sprinklers and pop-up sprays should
not be installed on the same watering zone.
INSPECTING THE FILTER
Unscrew the top (H) and lift the complete sprinkler
assembly (J) out of the can (K). The filter is located on
the bottom of the sprinkler assembly and can be easily
pulled out, cleaned and re-installed.
WINTERIZATION TIPS
When using an air compressor to remove water
from the system please note the following:
a. Do not exceed 30 PSI.
b. Always introduce air into the system gradually
to avoid air pressure surges. Sudden release of
compressed air into the sprinkler can cause damage.
c. Each zone should run no longer than 1 minute on
air. Sprinklers turn 10 to 12 time faster on air than
on water. Over spinning rotors on air can cause
damage to the internal components.
SETTING THE ARC ADJUSTMENT
(continued from reverse side)
SPRINKLER INSTALLATION
3
s
1
s
2
s
3
s
PERFORMANCE DATA
NOZZLE PRESSURE
RADIUS FLOW RATE
PRECIP
in/hr
/
mm/hr
PSI
kPa Bars Ft.
M. GPM L/M M
3
/H
n
s
n
s
#0.75
30 206 2.1 29 8.8 0.7 2.6 0.16 0.16 0.19
4
5
40 275 2.8 30 9.1 0.8 3.0 0.18 0.17 0.20
4
5
50 344 3.4 30 9.1 0.9 3.4 0.20 0.19 0.22
5
6
60 413 4.1 31 9.4 1.0 3.8 0.23 0.20 0.23
5
6
#1.0
30 206 2.1 30 9.1 0.9 3.4 0.20 0.19 0.22
5
6
40 275 2.8 31 9.4 1.0 3.8 0.23 0.20 0.23
5
6
50 344 3.4 31 9.4 1.2 4.5 0.27 0.24 0.28
6
7
60 413 4.1 32 9.8 1.3 4.9 0.30 0.24 0.28
6
7
#1.5
30 206 2.1 32 9.8 1.2 4.5 0.27 0.23 0.26
5
6
40 275 2.8 33 10.1 1.4
5.3 0.32 0.25 0.29 6 7
50 344 3.4 34 10.4 1.6 6.1 0.36 0.27 0.31
7
8
60 413 4.1 34 10.4 1.8 6.8 0.41 0.30 0.35
7
9
#2.0
30 206 2.1 34 10.4 1.6
6.1 0.36 0.27 0.31 7 8
40 275 2.8 36 11.0 1.8
6.8 0.41 0.27 0.31 7 8
50 344 3.4 38 11.6 2.0 7.6 0.45 0.27 0.31
7
8
60 413 4.1 38 11.6 2.2 8.3 0.50 0.29 0.34
7
9
#3.0
30 206 2.1 36 11.0 2.0
7.6 0.45 0.30 0.34 7 9
40 275 2.8 38 11.6 2.4
9.1 0.55 0.32 0.37 8 9
50 344 3.4
40 12.2 2.7 10.2 0.61 0.32 0.38 8 10
60 413 4.1
40 12.2 2.9 11.0 0.66 0.35 0.40 9 10
#4.0
30 206 2.1 36 11.0 2.6
9.8 0.59 0.39 0.45 10 11
40 275 2.8 40 12.2 3.0 11.4 0.68 0.36 0.42 9 11
50 344 3.4
42 12.8 3.4 12.9 0.77 0.37 0.43 9 11
60 413 4.1
42 12.8 3.7 14.0 0.84 0.40 0.47 9 12
#6.0
40 275 2.8 38 11.6 4.2 15.9 0.91 0.56 0.65 14 16
50 344 3.4 43 13.1 4.9 18.5 1.11 0.51 0.59 13 15
60 413 4.1
46 14.0 5.5 20.8 1.25 0.50 0.58 13 15
70 482 4.8 47 14.3 6.0 22.7 1.36 0.52 0.60 13 15
#8.0
40 275 2.8 45 13.7 6.0
22.7 1.36 0.57 0.66 14 17
50 344 3.4
48 14.6 6.8 25.7 1.54 0.57 0.66 14 17
60 413 4.1
49 14.9 7.6 28.8 1.73 0.61 0.70 15 18
70 482 4.8
51 15.5 8.2 31.0 1.86 0.61 0.70 15 18
LOW ANGLE PERFORMANCE DATA
NOZZLE PRESSURE
RADIUS FLOW RATE
PRECIP
in/hr
/
mm/hr
PSI
kPa Bars Ft.
M. GPM L/M M
3
/H
n
s
n
s
#1.0
30 207 2.0 22 6.7 1.2 4.5 .34 0.48 0.55 12 14
40 275 3.0 24 7.3 1.7 6.4 .39 0.57 0.66 14 17
50 344 3.5 26 7.9 1.8 6.8 .41 0.51 0.59 13 15
60 413 4.0 28 8.5 2.0 7.6 .46 0.49 0.57 13 14
#3.0
30 207 2.0 29 8.8 3.0 11.4 .68 0.69 0.79 18 20
40 275 3.0 32 9.8 3.1 11.7 .71 0.58 0.67 15 17
50 344 3.5 35 10.7 3.5 13.2 .80 0.55 0.64 14 16
60 413 4.0 37 11.3 3.8 14.4 .87 0.53 0.62 13 16
#4.0
30 207 2.0 31 9.4 3.4 12.9 .78 0.68 0.79 17 20
40 275 3.0 34 10.4 3.9 14.8
.89 0.65 0.75 16 19
50 344 3.5
37 11.3 4.4 16.7 1.00 0.62 0.71 16 18
60 413 4.0 38 11.6 4.7 17.8 1.07 0.63 0.72 16 18
#6.0
40 275 3.0 38 11.6 6.5 24.6 1.68 0.87 1.00 22 25
50 344 3.5 40 12.2 7.3 27.6 1.66 0.88 1.01 22 25
60 413 4.0
42 12.8 8.0 30.3 1.82 0.87 1.01 22 26
70 482 5.0
44 13.4 8.3 32.6 1.96 0.86 0.99
22 25
*All precipitation rates calculated for 180° operation.
For the precipitation rate for a 360° sprinkler, divide by 2.
Pre-
installed
RPS
®
75 Gear Driven Sprinkler Setting Instructions