PUMP START RELAY / MASTER VALVE WIRING
RAIN SENSOR INSTALLATION
This section is only for systems that require a pump
start relay or master valve. The controller does not
provide main power for a pump.
Master Valve or Pump Start
Relay wiring terminals
“COM” & “MV/PS” are
located at the lower right
corner of the cabinet.
NOTE: JUMPERS FOR
UNUSED STATIONS
To prevent pump or system
damage when using a pump
start relay, use a jumper to
connect all unused stations
to the last station with a
run time.
Unused station(s) without a
jumper could cause pump or
system damage should the
unused station be turned on.
Pump operation with no flow
(dead-head), could cause
over-pressurization of the
system or the pump to
overheat.
All electrical connections and wiring must
be made according to local building codes.
1. Open the cabinet door.
2. Open the front panel by grasping
the finger-hold on the top right side
of the front panel. Swing the panel
open to the left.
3. Connect the two rain sensor wires
to the two terminals marked SENSOR
located in the lower right corner of
the cabinet.
NOTE:
If a rain sensor has not been
installed in the PRO EX 2.0 controller, the
pre-installed jumper wire must remain
installed on the SENSOR terminals.
For wireless rain sensors needing
an additional power source, use the
VT terminal for 24VAC and use the
COM terminal for the common.
Both are located in the lower left
corner of the cabinet.
VALVE COMMON WIRE
VALVE WIRES
MASTER VALVE WIRE
MASTER
VALVE
VALVE COMMON WIRE
VALVE WIRES
MASTER VALVE WIRE
MASTER
VALVE