Installation
(continued)
Master Valve Installation
®
For a detailed illustration
of valve installation,
view
®
The purpose of the
master valve [connected
to the PUMP terminal] is to
shut off the water supply
to the irrigation system
when there is a faulty
valve or none of the zones
are operating correctly
®
It is used like a backup valve
or fail safe device and is
installed at the start of the
irrigation system where it
is connected to the water
supply line
Rain Sensor Connection
®
For a detailed illustration
of rain sensor connection,
view
®
A rain sensor detects rainfall
and tells the controller to
suspend watering, resuming
after the sensor dries out
®
This is wired between
the
SENSOR TERMINAL
[SENS] and the
COMMON
[COM] as shown below