30
7 TABLE 1: BURNERS AND NOZZLE SPECIFICATIONS
Adapting the Cooktop for Different Types of Gas
G20/ G25
G25.1
G27
G2.350
G30
G31
Burner
Ther
mal
power
(kW)
Nozzl
e
1/100
(mm)
Ther
mal
power
kW
Nozzl
e
1/100
(mm)
Ther
mal
power
kW
Nozzl
e
1/100
(mm)
Ther
mal
power
kW
Nozzl
e
1/100
(mm)
Ther
mal
power
kW
Nozzle
1/100
(mm)
Nozzle
1/100
(mm)
Nozzle
1/100
(mm)
Therm
al
power
(kW)
Nozzle
1/100
(mm)
Auxilia
ry
(Small)
(A)
1.0
71
1.0
75
1.0
79
1.0
98
1.0
52
47
45
1.0
52
Semi
rapid
(Mediu
m)
1.80
97
1.80
105
1.80
106
1.80
125
1.8
67
64
59
1.8
67
Rapid
(R)
2.40
110
2.40
118
2.40
120
2.40
138
2.40
77
72
67
2.4
77
Triple
Ring
(TR)
3.40
125
3.40
142
3.40
143
3.40
185
3.40
93
88
82
3.4
93
Supply
pressu
res
20
mbar
25
mbar
25mbar
20mbar
13mbar
30
mbar
37
mbar
50
mbar
37
Mbar
Factory setting for 2Z-KHGX-LPG: G30-50mbar
Factory setting for other Models: G20-20 mbar - G 25-25 mbar
At 15°C and 1013 mbar-dry gas
P.C.I.G20
37.78 MJ/m³
P.C.I.G25.1 32.51 MJ/m³
P.C.I.G25
32.49 MJ/m³
P.C.I.G27
30.98 MJ/m³
P.C.I.G2.350 27.20MJ/ m³
P.C.I.G30
49.47MJ/Kg
Replacement of burner nozzle: loosen the nozzle with a
dedicated wrench(7).Fit the new nozzle, suitable for the required gas
type (see table above for reference)
。
After you have converted the cooktop to another gas type, make sure you have placed a
label containing that information on the appliance.